F63 Change COM speed

0

 = 1200 Baud / 

1

 = 2400 Baud / 

2

 = 4800 Baud / 

3

 = 9600 Baud / 

4

 = 14400 Baud / 

5

 = 19200 

Baud / 

6

 = 38400 Baud (

default

) / 

7

 = 57600 Baud / 

8

 = 115200 Baud

For setting the communication speed used in the CRP (Came Remote Protocol) connection system.

F65  Wireless input RIO-EDGE [T1]

OFF

 (

default

) / 

P0

 = P0 / 

P7

 = P7 / 

P8

 = P8

RIO-EDGE wireless safety device associated to a function of choice among those available: P0= stop gate and exclude any automatic closing; to 
resume movement, use the control device, P7 = reopening during closing, P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.

 This function only appears is the control board has been fitted with a RIO-CONN card.

F66  Wireless input RIO-EDGE [T2]

OFF

 (

default

) / 

P0

 = P0 / 

P7

 = P7 / 

P8

 = P8

RIO-EDGE wireless safety device associated to a function of choice among those available: P0= stop gate and exclude any automatic closing; to 
resume movement, use the control device, P7 = reopening during closing, P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.

 This function only appears is the control board has been fitted with a RIO-CONN card.

F67  Wireless input RIO-CELL [T1]

OFF

 (

default

) / 

P1

 = P1 / 

P2 marked areas

 = P2 / 

P3

 = P3 / 

P4

 = P4

RIO-CELL is associated to any function chosen among those available: P1 = reopening during closing; P2 = reclosing during opening; P3 = partial 
stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.

 This function only appears is the control board has been fitted with a RIO-CONN card.

F68  Wireless input RIO-CELL [T2]

OFF

 (

default

) / 

P1

 = P1 / 

P2 marked areas

 = P2 / 

P3

 = P3 / 

P4

 = P4

RIO-CELL is associated to any function chosen among those available: P1 = reopening during closing; P2 = reclosing during opening; P3 = partial 
stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.

 This function only appears is the control board has been fitted with a RIO-CONN card.

F71  Partial opening time

5

 = 5 seconds (

default

) /....... / 

40

 = 40 seconds

After an opening command from the button connected to 2-3P, the gate opens for an adjustable time of between five seconds and 40 seconds.

U 1 Entering a user

1

 = Step-step command (open-close) / 

2

 = Sequential command (open-stop-close-stop) / 

3

 = Open 

only command / 

4

 = Partial opening command

Entering up to 250 users and associating to each one a function of choice among those included. This must be done via transmitter or other control 
device (see "ENTERING USERS WITH ASSOCIATED COMMAND paragraph).

U 2 Deleting a user

Deleting a single user

U 3   Deleting users

OFF

 (

default

) / 

ON

 = Delete all users

Deleting all users.

U4  Code decoding

1 (default) / 2 / 3

For choosing the type of receiving control code: 1= all series / 2 = only 

Rolling Code

 series / 3 = only TWIN series

 When you select a radio code, all saved transmitters will automatically be deleted.

 The TWIN code lets you save multiple users with the same key, that is, key block.

A 4 Resetting parameters

OFF 

(

default

) / 

ON

Attention! The default settings will be restored.

A 5   Counting maneuvers

Number of maneuvers done

For viewing the number of maneuvers completed or for deleting them (001 = 100 maneuvers; 010 = 1,000 maneuvers; 100 = 10,000 maneuvers; 
999 = 99,900 maneuvers; CSI = maintenance job)

H1 Version

View the firmware version.

Summary of Contents for BK Series

Page 1: ...Sliding gate operator BK series BK 800 1200 1800 2200 1210 1810 2210 INSTALLATION OPERATION AND MAINTENANCE MANUAL EN English FA01161 EN...

Page 2: ...Manual FA01161 EN 08 2018 CAME S p A The contents of this manual may change at any time and without notice Original instructions...

Page 3: ...0 V AC Card 630 mA F Accessories 1 A F DESCRIPTION OF PARTS 1 Power supply terminals 2 Terminal for gearmotors 3 Terminals for signaling devices 4 Transformer terminals 5 Control board fuse 6 Accessor...

Page 4: ...ORY WIRING Flashing light connection output contact rated at 230 V AC 25 W max SIGNALING DEVICES Closing limit switch micro switch WHITE RED ORANGE Condenser 230V AC Gearmotor Gate open signal output...

Page 5: ...t OPEN CLOSE INVERT function step step from control device NO contact Alternatively from the functions programming you can activate the single command OPEN STOP CLOSE STOP sequential See function F7 O...

Page 6: ...movement until the gate is fully open again C2 closing during opening When the gate is opening opening the contact triggers the inversion of movement until the gate is completely closed C3 partial sto...

Page 7: ...e operator and this error will show up on the display as E17 Fit the RSE card WARNING For the system to work properly before fitting the control board you MUST CUT OFF THE POWER MAINS and remove any e...

Page 8: ...e safety edges with clean contact C8 reclosing during opening by sensitive safety edges with clean contact r7 reopening during closing for sensitive safety edges 8K2 resistive input r8 reclosing durin...

Page 9: ...automatic closing wait starts when the opening limit switch point is reached and can be set to between 1 and 180 seconds The automatic closing does not activate if any of the safety devices trigger wh...

Page 10: ...s function only appears is the control board has been fitted with a RIO CONN card F68 Wireless input RIO CELL T2 OFF default P1 P1 P2 marked areas P2 P3 P3 P4 P4 RIO CELL is associated to any function...

Page 11: ...ng users the flashing numbers appearing are those numbers that are available and usable to assign to a new user max 250 users Before registering the users make sure the AF radio card is plugged into t...

Page 12: ...stem s user and configuration data by using the Memory Roll so they can be used with another control board even on another system Warning Fitting and extracting the Memory Roll must be done with the m...

Page 13: ...92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 Manual FA011...

Page 14: ...176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225...

Page 15: ...perator is up and running and the users are registered refit the covers without pinching any wires Fasten them with screws ERROR MESSAGES The error messages are shown on the display E 4 Safety test er...

Page 16: ...the ENTERING USERS WITH ASSOCIATED COMMANDS DISMANTLING AND DISPOSAL CAME S p A applies a certified Environmental Management System at its premises which is compliant with the UNI EN ISO 14001 standar...

Page 17: ...iri Della Libert 15 31030 Dosson di Casier Treviso Italy tel 39 0422 4940 fax 39 0422 4941 Manual FA01161 EN 08 2018 CAME S p A The contents of this manual may change at any time and without notice Or...

Reviews: