4
43,5
45
7,5
57
70
106
A
B
64,5
70
145
A
B
M2
M1
+
–
1
1
2
4
5
3
VAS/101-CM
PLACO-C
EN
Technical features
Power supply:
230 VAC 50-60 Hz
Current absorbed
I
max 200 mA
AC
AC
Power dissipated:
10 W max
Rated power supply:
18 VDC 1 A-0.5 A 1’/3’
Dimensions:
4 DIN
Storage temperature:
-25 °C + 70 °C
Operating temperature:
0 °C +35 °C
IP degree:
IP 30
Wall mounting
With the Allen wrench, unscrew the blocking screws and remove the plate (figure 1). Fix the given plugs and
screw the entry panel (figure 2) at the desired height. Run the sheath with the system conductors as shown
in figure 2.
Extract the plastic terminal cover and wire the connections (figure 3). Once all the connections have been
made, re-insert the terminal covers. Install the front plate (figure 1).
Recessed installation
Install the recessed box at the desired, but in advance, run the sheath with the system conductors through one
of the breaking points (figure 4 point A).
During installation of the recessed box it is possible to avoid any deformation by using the provided spacer
(figure 4 point B).
With the Allen wrench, unscrew the blocking screws and remove the entry panel plate (figure 1).
Introduce the cable connections in the special hole (figure 2) and fix the entry panel on the frame as shown in
figure 5; extract the plastic terminal cover and wire the connections (figure 3).
Once all the connections have been made, re-insert the terminal covers.
Install the front plate (figure 1).
Installation
The power supplier must ALWAYS be installed vertically.
The unit can be installed on a DIN guide (EN 50022) in a special electrical panel.
For the overall dimensions, see fig. 1.
Provide sufficient ventilation if the power supplier is installed in a container.
Terminal boards
M1
~
Mains
~
M2
–
+
18 VDC power supply (*)
(*) The unit is protected against overloads and
short circuits.