background image

p.

 

9

 

- M

an

u

al

 c

od

e: 

F

A

0

0

0

2

1

-E

N

F

A

000

2

1

-E

N

 v.

 

4

 

11

/2

0

1

6 © C

A

M

E S

.p.

A

. T

h

e c

onte

nt

s o

f th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed at a

ny ti

m

e w

ith

ou

t p

ri

or n

oti

ce

.

Lubricate the bushing 

 and fit it into one of the holes on the post bracket.

Fasten the joint to the post bracket 

 using the M8 x 35 bolt and UNI 7474 M8 nut.

Fastening the gearmotor

Fasten the bracket to the post 

using suitable anchors and screws. If the post is made of metal, the bracket can 

be welded to it.
Note: the holes on the bracket are for further opening angle variations of the gate leaf.
Fasten or weld the bracket to the gate 

 .

Summary of Contents for AXI SWN20

Page 1: ...GEARMOTOR FOR SWING GATES AXI Installation manual SWN20 SWN25 FA00021 EN English EN ...

Page 2: ... WHEN HANDLING GEARMOTORS THAT WEIGH OVER 20 KG IF NEED BE USE PROPER SAFETY HOISTING EQUIPMENT ALL OPENING COMMANDS THAT IS BUTTONS KEY SWITCHES MAGNETIC READERS AND SO ON MUST BE INSTALLED AT LEAST 1 85 M FROM THE PERIMETER OF THE GATE S WORKING AREA OR WHERE THEY CANNOT BE REACHED FROM OUTSIDE THE GATE ALSO ANY DIRECT COMMANDS BUTTONS TOUCH PANELS AND SO ON MUST BE INSTALLED AT LEAST 1 5 M FROM...

Page 3: ...RATION TO PREVENT POTENTIALLY HAZARDOUS SITUATIONS READ THE INSTRUCTIONS IF THE POWER SUPPLY CABLE IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER OR AUTHORIZED TECHNICAL ASSISTANCE SERVICE OR IN ANY CASE BY SIMILARLY QUALIFIED PERSONS TO PREVENT ANY RISK IT IS FORBIDDEN FOR USERS TO PERFORM ANY OPERATIONS THAT ARE NOT EXPRESSLY REQUIRED OF THEM AND WHICH ARE NOT LISTED IN THE MANUALS FOR ANY R...

Page 4: ...em crown and conical torque Intended use This gearmotor is designed to power and operate swing gates in private homes and apartment blocks Any installation other than what is detailed in this manual is prohibited LEGEND This symbol shows which parts to read carefully This symbol shows which parts describe safety issues This symbol shows which parts to tell users about It always advisable to fit an...

Page 5: ...ower W 120 Duty cycle 50 Opening time at 90 s 15 Operating temperature C 20 55 Apparatus class 3 Reduction ration i 1 36 Thrust N 400 2000 Weight Kg 5 5 6 The weight of the gearmotor includes the brackets The motor s net weight is xx Kg The weight of the gearmotor includes the brackets The motor s net weight is xx Kg Dimensions mm Smallest reference value with fastest travel and slowest slow down ...

Page 6: ...rking order and lubricated check that distance C does not exceed the reference table value make sure there are opening and closing mechanical gate stops make sure that the point where the gearmotor is fastened is protected from any impacts and that the surface is solid enough make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installatio...

Page 7: ...ansmitters 2 x 0 5 mm2 2 x 0 5 mm2 Photocell receivers 4 x 0 5 mm2 4 x 0 5 mm2 Command and safety device 2 x 0 5 mm2 2 x 0 5 mm2 Antenna The RG58 antenna max 10 m If cable lengths differ from those specified in the table establish the cable sections depending on the actual power draw of the connected devices and according to the provisions of regulation CEI EN 60204 1 For multiple sequential loads...

Page 8: ...ckets Establish the gate bracket fastening point and find the bracket s fastening point to the post while respecting the quotas shown in the drawings and tables Opening A mm B mm C mm E mm 90 130 110 170 0 60 750 115 150 110 160 0 50 750 Laying the corrugated tubes Set up the junction boxes and corrugated tubes you will need to make connections coming from the junction pit To connect the gearmotor...

Page 9: ...he holes on the post bracket Fasten the joint to the post bracket using the M8 x 35 bolt and UNI 7474 M8 nut Fastening the gearmotor Fasten the bracket to the post using suitable anchors and screws If the post is made of metal the bracket can be welded to it Note the holes on the bracket are for further opening angle variations of the gate leaf Fasten or weld the bracket to the gate ...

Page 10: ...re loose and fit the pin into the gate bracket Fasten using the UNI6593 washer Ø 10 and the supplied UNI 5739 M10 X 10 bolt b Establishing the limit switch points DO NOT REMOVE cover 1 without first sliding it Before establishing the endstop points you need to release the gearmotor see paragraph on manually releasing it and remove covers 1 and 2 while carefully following the illustrations ...

Page 11: ...out first sliding it For opening Reach the gate leaf opening point you want and take the mechanical stop to rest using the slide guide Fasten the closing mechanical stop s grub screws For closing Close the gate leaf completely and rest it against the mechanical stop using the slide guide Fasten the closing mechanical stop s grub screws CONNECTIONS TO THE CONTROL PANEL ...

Page 12: ... B Cut and fasten post bracket by supplementing it with an additional bracket not issued Open the gate max 90 establish the quota E and establish the gate bracket fastening point Fasten the bracket Connecting two gearmotors Connecting one gearmotor Gearmotor with encoder M2 24 V DC Gearmotor with encoder M2 24 V DC delayed when closing Gearmotor with encoder M1 24 V DC delayed when opening Opening...

Page 13: ... necessary electrical connections as shown in the figure Gearmotor with encoder M1 24 V DC delayed when closing Gearmotor with encoder M2 24 V DC delayed when opening FINAL OPERATIONS Fastening the covers Once you have completed all electrical connections and commissioning fit the covers as shown here YOU MUST first slide the covers forward and then snap them down into place ...

Page 14: ...OR RELEASING PROBLEM POSSIBLE CAUSES FIXES AND REMEDIES It neither opens nor closes Power supply is missing The gearmotor is stuck The transmitter s battery is run down The transmitter is broken The stop button is either stuck or broken The opening closing button or the key switch selector is stuck Check main power supply Call assistance Replace the batteries Call assistance Call assistance Call a...

Page 15: ...______ _____________________________________________________________________________ ____________________________________________________________________________ Extraordinary maintenance The following table is for logging any extraordinary maintenance jobs repairs and improvements performed by specialized contractors Any extraordinary maintenance jobs must be done only by specialized technicians ...

Page 16: ...ste for recycling Always make sure you comply with local laws before dismantling and disposing of the product DO NOT DISPOSE OF IN NATURE DISMANTLING AND DISPOSAL Our products are made of various materials Most of these aluminum plastic iron electrical cables are classified as solid household waste They can be recycled by separating them before dumping at authorized city plants Whereas other compo...

Reviews: