Determining the closing end-of-travel points
Perform these operations on both gearmotors.
Release the gearmotor.
Manually close the leaf to the desired point.
Disconnect the 9-pole terminal board.
Connect the multimeter set to check continuity to the Ra-Ra terminals (NC contact); a buzzer will sound on the multimeter.
Turn the shaft (A) CLOCKWISE to determine the closing travel end point, until the Ra-Ra contact opens and the multimeter stops buzzing.
Leave the rod nut loose to determine the end-of-travel points.
M N Rc Rc
Ra Ra
+ E -
Ω
V
Hz
After adjusting the travel end points, run travel self-learning from the control panel, following the instructions in the control panel manual.