Main points of danger for people

No transiting while the barrier is moving.

Risk of entrapment.

Risk of trapping hands.

Risk of trapping feet.

Risk of cutting hands.

DISMANTLING AND DISPOSAL

 CAME S.p.A. employs an Environmental Management System at its premises. This system is certified and compliant with the UNI EN ISO 14001 standard to ensure 

that the environment is respected and safeguarded. Please continue safeguarding the environment. At CAME we consider it one of the fundamentals of our operating and 
market strategies. Simply follow these brief disposal guidelines:

 DISPOSING OF THE PACKAGING

The packaging materials (cardboard, plastic, etc.) can be disposed of easily as solid urban waste, separated for recycling.
Before dismantling and disposing of the product, please always check the local laws in force.
DISPOSE OF THE PRODUCT RESPONSIBLY.

 DISPOSING OF THE PRODUCT

Our products are made of various materials. Most of these materials (aluminium, plastic, iron and electrical cables) are classified as solid urban waste. They can be 
separated for recycling and disposed of at authorised waste treatment plants.
Other components (electronic boards, transmitter batteries, etc.) may contain pollutants.
These must be removed and disposed of by an authorised waste disposal and recycling firm.
It is always advisable to check the specific laws that apply in your area.
DISPOSE OF THE PRODUCT RESPONSIBLY. 

Summary of Contents for ATS50DGM

Page 1: ...Swing gate gearmotor ATS30DGS ATS50DGS ATS30DGR ATS30DGM ATS50DGM INSTALLATION MANUAL FA01561 EN EN English...

Page 2: ...Page 2 Manual FA01561 EN 02 2023 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions 1 2 3 1 2 3 4...

Page 3: ...unauthorised personnel from entering especially minors In case of manual handling have one person for every 20 kg that needs hoisting for non manual handling use proper hoisting equipment in safe con...

Page 4: ...trategies Simply follow these brief disposal guidelines DISPOSING OF THE PACKAGING The packaging materials cardboard plastic etc can be disposed of easily as solid urban waste separated for recycling...

Page 5: ...ith encoder for swing gates with Max C up to 200 mm with leaf up to 5 m and 400 kg Grey RAL7024 801MP 0110 ATS30DGR Irreversible telescopic gearmotor 24 V with encoder for swing gates with max C 200 m...

Page 6: ...otor 1 Gate bracket 2 Door to access the end of travel adjustment screws 3 Door to access the release mechanism 4 Sheath connector 5 Pillar bracket 6 Release key 7 Release cord 8 Cutting hazard labels...

Page 7: ...keep it at room temperature where it has previously been stored or transported at a very high or very low temperature The average product life specified should be understood purely as an indicative e...

Page 8: ...for fitting the operator and accessories varies depending on the area where it is installed It is up to the installer to find the most suitable solution The drawings refer to a gearmotor installed on...

Page 9: ...or 120 First determine where the gate bracket needs to be positioned then where the post bracket needs to be positioned Respect the values indicated in the table A C B 60 60 E F 5 ATS30DGS ATS30DGR AT...

Page 10: ...without notice Translation of the original instructions Fastening the brackets Secure the post bracket with plugs and screws The holes on the bracket fixing plate allow you to vary the opening angle o...

Page 11: ...hanged at any time and without notice Translation of the original instructions Fastening the gearmotor Lubricate all moving parts on the operator A The self locking nut must be loosely tightened so as...

Page 12: ...ICAL CONNECTIONS Before working on the control panel disconnect the mains power supply and remove the batteries if any Remove the protective cover to access the terminal block A Control panel B Gearmo...

Page 13: ...orm these operations on both gearmotors Release the gearmotor Manually open the leaf to the desired point Disconnect the 9 pole terminal board Connect the multimeter set to check continuity to the Ra...

Page 14: ...d on the multimeter Turn the shaft C ANTICLOCKWISE to determine the closing travel end point until the Rc Rc contact opens and the multimeter stops buzzing If you want to decrease the closing angle th...

Page 15: ...where to fasten the brackets Close the gate manually First determine where the gate bracket needs to be positioned then where the post bracket needs to be positioned Respect the values indicated in th...

Page 16: ...ical connections Before working on the control panel disconnect the mains power supply and remove the batteries if any Remove the protective cover to access the terminal block A Control panel B Gearmo...

Page 17: ...l range To move the microswitch 10 mm in either direction turn the rod 20 times A C Determining the opening end of travel points Perform these operations on both gearmotors Release the gearmotor Manua...

Page 18: ...t the 9 pole terminal board Connect the multimeter set to check continuity to the Ra Ra terminals NC contact a buzzer will sound on the multimeter Turn the shaft A CLOCKWISE to determine the closing t...

Page 19: ...ance If the system is not used for long periods of time e g for installations at sites with seasonal closures disconnect the power supply When the power supply is reconnected check the system is worki...

Page 20: ...AME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions CAME S p A Via Martiri della Libert 15 31030 Dosson di Casier Treviso Italy...