background image

TITLE

commissioning 

the rgsm

3.8 Manual 

Add

Enter the “Keycode” located on the 
front of the RGSM0001S. Enter a 
“Name” and “Description” followed 
be “Add”.

3.5

 Select the site you have 

created.

3.6 

Press “Add gateway”.

3.7 

Press ‘Manual Add’.

OUT1

OUT2

Keycode

123456789ABCDE F

MATR

54051 6

300mAE

GSM – 900  33dBm

DCS – 1800   30dBm

869.5MHz     14dBm  

24V

CONNECT

123

4

GND

A
N
T

10

+

2

COM

IN2

COM

IN1

B
A

 1A 30V

RGSM001S

1

2

3

troubleshooting

If you have any problems 

setting up your RGSM, visit our 

troubleshooting page:

123456789ABCDEF

SIM ID 8988228066602040825

Mr Wilson, Sills Rd, DE74 2US

3.9 

The RED 

3

 and GREEN 

2

 LED’s will now be 

on solid and the BLUE 

 flashing 1x/sec.

CONGRATULATIONS - the RGSM001S has now 

been successfully added to the Connect platform

OUT1

OUT2

Keycode

123456789ABCDE F

MATR

54051 6

300mAE

GSM – 900  33dBm

DCS – 1800   30dBm

869.5MHz     14dBm  

24V

CONNECT

123

4

GND

A
N
T

10

+

2

COM

IN2

COM

IN1

B
A

 1A 30V

RGSM001S

If you intend to retain control  

of the SIM for top up

 

If, as the installer, you intend to retain control of the SIM 

for top up purposes, we recommend that you complete 

the ‘Name’ field with information relating to the customer, 

property or site and in the ‘Description’ field you insert 

the SIM number which will give you full visibility of the site 

information and the description in the installer SETUP app.  

However, If you are transferring  

the SIM control to your end user 

If you intend to transfer control of the SIM for top up 

purposes to your end user, we recommend that the 

Device Name should be labeled with the SIM number t

provide your end user long term visibility in the dedicated 

end user Automation App. 

 

Please Note:

The ‘Description’ field is not visible in the end user 

Automation App, therefore any information contained 

within that field will not be available to the end user 

after handover. The description field is only visible in the 

Installer SETUP App.

Summary of Contents for ATS-P524

Page 1: ...Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety Complete kit for a pair of swing gates weighing up to 400kg per leaf max width 5m TO BE READ IN CON...

Page 2: ...SM001S Gateway Module RSE Connection Card SIM May be preinstalled in RGSM001S 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Wiring Diagram 7 Pre...

Page 3: ...ssing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless they are in view Do not attempt to block or interfere with the gate...

Page 4: ...lands to connect the devices to the control panel One of these must be used exclusively for the power supply cable All holes should be sealed to avoid ingression and maintain the IP54 protection ratin...

Page 5: ...F mm C max mm 90 200 200 1030 1430 150 90 200 270 1030 1510 200 120 200 140 1030 1460 70 Preliminary checks Side hung gate GEOMETRY 5m Tick 1 Check that the gate structure is sturdy enough the hinges...

Page 6: ...refully at the same speed as the automatic operator 4 To re engage close the gate and turn the key back to its original position D Attempt to manually move the gate to ensure it is fully engaged Basic...

Page 7: ...r to OFF TOP A433N Antenna Cable length RG58 Max 5m DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m 10 2 TX C NC TX 2 RX TX RGSM001S Gateway Module Cable length Max 3m pow...

Page 8: ...rength or availability and therefore will not be held liable for lack of service came automation internet came cloud setup app for the installer GET IT ON AppStore GET IT ON automation app for the end...

Page 9: ...ction using control panel CAUTION Ensure the gate movement area is clear of all obstructions Check the motor direction A 2 O N For motor 2 Press and hold The gate should open if not reverse the motor...

Page 10: ...rrive please check your junk folder download the connect setup app adding the rgsm gateway to your technician account technician connect setup app 1 3 2 If you have an existing account please move to...

Page 11: ...Bm 24V CONNECT 123 4 GND A N T 10 2 COM IN2 COM IN1 B A 1A 30V RGSM001S If you intend to retain control of the SIM for top up If as the installer you intend to retain control of the SIM for top up pur...

Page 12: ...dd automation Select Manual Add Select ZL65 ZL65 from the drop down list Enter a name and description then press Add adding automation 1 ZL65 ZL65 Automation for swing gates Encoder Axo ATS M1 M2 Fron...

Page 13: ...ition or Add with QR Code If you pressed Local Acquisition the screen will change to the one shown here Select the button on the fob and it will add the button straight onto the control panel Set the...

Page 14: ...cess for all fobs Select the back button to return to the main menu If you select ADD via QR Code the app will open the devices camera enabling scanning of the QR code on the fobs packaging Once the Q...

Page 15: ...n App On first login you will be prompted to accept the gateway You will then be presented with control options for your automation To transfer to a customer select the 3 dots Select Transfer site Ent...

Page 16: ...te motor complete the following steps Send an opening command pulse using a link wire between terminal 2 7 While the motor is running turn the rod marked A clockwise until the motor stops running Note...

Page 17: ...saved remove a transmitter button 1 Press and hold the button for 2 seconds to access programming F 1 appears on the display 2 Remove a transmitter button U 2 O N 3 Use the arrow buttons to choose the...

Page 18: ...quire activation from a command device to restart C1 REOPENING DURING CLOSING When the automation is in its closing cycle and the safety circuit is triggered the automation will stop and reverse its m...

Page 19: ...and fit the replacement SIM card into the slot Replace the casing and power up the control panel Send an SMS to the telephone number of the SIM reporting the APN details Access Point Name ask the serv...

Page 20: ...colour 806SL 0240 SELB1SDG2 Surface mounted with blue backlighting for 50 users RAL7024 Grey colour 806SL 0250 SELB1SDG3 Surface mounted with blue backlighting for 250 users RAL7024 Grey colour TRANS...

Page 21: ...tiple pairs of photocells can be applied to the same system even at double height and or close to each other with no interference issues cross talk 001DIR10 Pair of 12 24 V AC DC outdoor photocells ra...

Page 22: ...correct use of the Software requires the possession of an automation home automation security temperature control and or video surveillance system manufactured by Came which has been enabled for remo...

Page 23: ...ation of the automation home automation security temperature control and or video surveillance system manufactured by Came may be associated with the system itself In this way the installer can perfor...

Page 24: ...immediate effect in the event of the violation of the terms of Articles 2 2 and or 2 5 In this case termination shall occur automatically upon receipt by the Installer of the notification sent by Came...

Page 25: ...vidual parts of the additional network services and other related services referred to in Section 3 1 lit c of these GTC 1NCE expressly points out that the type and scope of such services of the respe...

Page 26: ...tion 2 of these GTC for the Services Within the framework of the conclusion of the contract the Customer may choose between different payment methods offered by 1NCE Unless otherwise agreed between th...

Page 27: ...a Protection Act Bundesdatenschutzgesetz 10 2The Parties also undertake to treat all other confidential information of the other Party that the receiving Party becomes aware of in connection with the...

Page 28: ...THIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S P A E OE CAME BPT North Unit 1B Sills Road Willow Far...