11 - FA00489M4A - ver. 1 - 03/2017
ENGLISH
General Precautions
Important people-safety instructions: READ CAREFUL-
LY!• Installing, programming, commissioning and mainte-
nance must only be done by qualified, expert staff and in
full compliance with the applicable law. • Wear anti-static
footwear and clothing when working on the control board.
• Keep these precautions. • This product should only be
used for the purpose for which it was explicitly designed.
There is danger of the battery exploding if it is replaced
with the wrong type. • The batteries, once their life-cycle is
exhausted, must not be thrown among the non-separated
garbage, but rather, collected and sent to a proper disposal
center. • Keep the batteries away from children's reach. • If
swallowed, seek immediate medical attention.
Description
Double-technology- passive infrared and microwave - ra-
dio-based, outdoor sensor.
The sensor is removal-protected by a built-in tamper-proof
system.
Description of parts
B
1
Signaling LED
B
Dip-switch
C
Jumpers
D
Potentiometer for setting
the infrared beam
E
Potentiometer for setting
the micro-waves
F
Anti-removal Tamper
LED legend
LEDs
Color
Meaning
DL1
Red
IR detection
DL2
Red
Microwave detection
DL3
Blue
Alarm
DL4
Red
Learning
DL5
Green
Learning
Description of Jumpers
JP1
Tamper Enabling/disabling
OPEN
Enabled
CLOSED
Disabled
JP2
Anti-Tampering Enabling/disabling
OPEN
Enabled
CLOSED
Disabled
JP3
Enabling/disabling the DL3 alarm LED
OPEN
Disabled
CLOSED
Enabled
Dip-switch description
DEFAULT
DIP1 Supervision
ON
Enabled
OFF
Disabled
DIP2 (Radio test)
ON
Enabled (transmits
every second)
OFF
Disabled. Normal ope-
ration
DIP3 Operating modes
ON
Test
OFF
Normal
Only switch DIP when there is no detection (if the LEDs are
enabled, switch the DIP-switch when they are all opened). The
sensor confirms switching into either test or normal mode, by
sounding off:
- TEST -> NORMAL: some quick "beeps"
- NORMAL -> TEST: long "beep"
If no sound is emitted this means that the sensor did not
switch to the chosen mode: in this case repeat the switching
of DIP3.
DIP4 Adjusting LEDs and BUZZER
ON
DL1, DL2 and BUZZER
enabled.
OFF
DL1, DL2 and BUZ-
ZER disabled. DL3 is
controlled by JP3. Use
this mode during nor-
mal operating mode
to increase the bat-
tery life.
DIP5-DIP6 Walk test
OFF
Normal operation
ON
IR Walk Test ope-
ration (DL1 is on
permanently)
OFF
ON
MW Walk Test operation (DL2 is on permanently)
OFF
The Walk Tests are for making adjustments to the sensor's
detection area. The infrared and microwave adjustments are
independent.
DIP7 IR range
ON
Max range about 18 m.
Adjsuting the max ran-
ge (via
RV1
) = about 9
÷ 18 m
OFF
Max range about
12 m. Max range
adjustment (via
RV1
)
= about 3 ÷ 12 m
Each time DIP7 is switched, wait 10 to 20 seconds.
Technical data
Type
PXWDTVE
Power supply
two 3V, CR123A,
Lithium batteries
Frequency (MHz)
433.92/868.65
Absorption when on standby (uA)
40
Absorption when alarm is triggered
(mA)
< 80
Radio signal power (dBm)
< 10
Microwave frequency (GHz)
24
Maximum range at 25 °C (m)*
12
Minimum range at 25 °C (m)*
3