A
43,5
45
7,5
57
70
106
A
B
64,5
70
145
43,5
45
7,5
57
70
106
A
B
64,5
70
145
M2
M1
+
–
a
Pa
ge
5
- M
an
ua
l F
A0
095
9-
EN
- v
er
s.
1 - 1
0/
20
17
- © C
am
e S
.p
.A
. - T
he c
ont
ent
s o
f t
hi
s m
an
ua
l m
ay b
e c
ha
ng
ed
, a
t a
ny t
im
e, a
nd w
ith
ou
t n
ot
ic
e.
001DC002AC
Installation
The power supplier must ALWAYS be installed horizontally. The device can be
installed on a DIN rail (EN 50022) in an appropriate electric panel.
NOTE. Proper ventilation is required if the power supplier is installed in a
metal container.
Technical features
Type
001DC002AC
Power supply [V AC]
230
Max current demand [A AC]
0,2
Max energy dissipation [W]
10
Nominal power supply [V DC]
18
Nominal current demand [A DC]
1 for 1’
Nominal current demand [A DC]
0.5 for 3’
Storage temperature [°C]
-25 ÷ +70
Operating temperature [°C]
0 ÷ +35
IP Rating [IP]
30
Features
A
Terminal board
a
~
Mains
~
Terminal board
–
+
Power supply 18 VDC (*)
(*) The appliance is electronically protected against overloads and short
circuits.