CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page
28
- Manual
FB00840-EN
- vers.
1
- 09/2017 - © C
ame S.p.A. - The cont
ents of this manual may be changed, at any time, and without notice.
Type
TH/550 Wi-Fi
Power supply 50/60 Hz (V AC)
230
Current consumption (mA)
10
Autonomous life without power supply (hours)
10
Standard wireless (IEEE)
802.11b, 802.11g, 802.11n
Wireless frequency field (MHz)
2.412 - 2.472
Maximum transmission power (dBm)
20
Wireless safety
WPA/WPA2-PSK, WEP
Relay maximum voltage (V)
250
Relay maximum current with resistive load (A)
5
Relay maximum current with inductive load (A)
2
Type of relay action
1B-U
Nominal impulse voltage (KV)
4
Reinforced electrical insulation between accessible parts, and
terminals (class)
II
Degree of pollution
II
Software class
A
Resolution temperature reading (°C)
0.1
Accuracy of internal probe (°C)
≤ ±0.5
Clock accuracy, maximum error (sec/day)
±1
Adjustment range (°C)
from +3 to +35
Room temperature measuring interval (seconds)
15
Maximum control unit temperature (°C)
40
No. of available NA and NC contacts
1
IP Protection rating:
30
Operating temperature (°C)
from 0 to +40
Maximum operating relative humidity without condensation (%)
93
Dimensions (mm)
126 x 94 x 23
Technical data