A
B
C
Page
20
- Manual
FB00805-EN
- ver
. 1
- 07/2017 - © C
AME S.p.A. - The cont
ents of this manual ar
e subject t
o change at any time without prior notice.
Remote activation via phone (only on battery-powered model)
By connecting a suitable telephone interface to the terminals
you can carry out two types of activation
from your phone:
1.
Remote activation of the timed Manual program:
to activate this program the input (terminals
)
must be closed for at least 2 secs and not more than 5 secs. WARNING: timed manual mode can be disabled
in advance by closing the input (terminals
) for at least 2 secs and not more than 5 secs.
2.
Remote activation of Manual program:
to activate this program it is necessary to close and keep closed
the input (terminals
); reopening the input causes deactivation of the manual program and takes
the device back to its previous conditions.
Compiling the timed manual program remotely
If you have chosen to connect to the terminals
a suitable telephone interface
A
( ), pressing the button brings up the
screen in figure
B
.
Using the
arrows the reference temper-
ature for the two types of remote activation
can be set.
Note. A reference temperature must be set
for the Heating mode and one for the
Cooling mode .
Pressing the button brings up the screen
in figure
C
.
Using the
arrows the duration (in
hours) of the timed manual program can
be set remotely.
Press the button to move on to the next