CAMDEN EXACT CX-DA400 Installation Instructions Manual Download Page 2

Page 2 of 6

CX-DA400 Door Prop Alarm Installation Instructions

•  Silent Time

 - “Open Door” Time - 0-2.5 min. in standard mode,  

3 - 90 min. in Extended mode (selected by Jumper 9).

•  Alarm Delay

 - “Warning” Time - 0-5 min. and “Infinite.” Local 

Beeping Warning Audible sounds during this time. 

•  Auto Reset

 - “Alarm” Time - 0-5 min. and Manual Reset. 

Constant Alarm Audible sounds during this time. 

•  Shunt Delay

 - Valid Access Time prior to reset if Door is 

unopened.  0, 5, 10, or 20 seconds (set with Jumpers 7 & 8).

TIMERS

SET

ALARM

DELAY

TIME

SELECT

AUTO

RESET

TIME

SELECT

 0

0 Sec

3 Min

0 Sec

0 Sec

 1

3 Sec

3.5 Min

3 Sec

3 Sec

 2

5 Sec

4 Min

5 Sec

5 Sec

 3

7 Sec

4.5 Min

7 Sec

7 Sec

 4

10 Sec

5 Min

10 Sec

10 Sec

 5

12 Sec

6 Min

12 Sec

12 Sec

 6

15 Sec

7 Min

15 Sec

15 Sec

 7

20 Sec

8 Min

20 Sec

20 Sec

 8

25 Sec

9 Min

30 Sec

30 Sec

 9

30 Sec

10 Min

45 Sec

45 Sec

 A

35 Sec

20 Min

1 Min

1 Min

 B

45 Sec

30 Min

2 Min

2 Min

 C

1 Min

40 Min

3 Min

3 Min

 D

1.5 Min

50 Min

4 Min

4 Min

 E

2 Min

60 Min

5 Min

5 Min

 F

2.5 Min

90 Min

INFINITE

MANUAL

TIMER SETTING TABLE

SIDE VIEW

NORMAL

  

Jumper OFF

EXTENDED

  

Jumper ON

SILENT TIME  

SELECT 

(Extended Silent Time Jumper)

TAMPER CIRCUIT

- Alarm is not reset with key. 

 

(CX-DA401 only)

•  TAMPER SWITCH

 - Switch is located on stand-off under spring steel 

actuator. (Cut cable tie to Enable switch)

•  DOOR SUPERVISION

 - Enable with Jumper 1. Requires resistors on 

Door Switch. (Schematic on Step 1 Pg.3)

OPERATION

VALID ACCESS / PROPPED DOOR OPERATION

ARMED STATE -

 Red LED (Green if Intrusion Detect is Off)

VALID USER INPUT -

 Shunt or Voltage Sense Input

LED - Changes to Green
DOOR - Opened by user, Silent Timer begins
DOOR - Closed by user, Returns to Armed State, or

 

- SILENT TIME TIMER

 - expires, then

 

AUDIBLE WARNING - Beeps to alert user locally

 

LED - Flashes Green

 

DOOR - Closed by user, returns to Armed State, or*

 

- SHUNT RECYCLE

 - 2nd Valid User Input (*if enabled) 

 

SILENT TIME RESET - Silent Timer begins again 

DOOR HELD/PROPPED 

- Alarm Delay Times out

LED - Flashes Red
AUDIBLE - Constant tone, Auto Reset (AR) Timer begins
OUTPUT - Door Prop Alarm relay toggles

DOOR CLOSED 

- After Door Prop Alarm exists 

AUDIBLE - On until Auto Reset (AR) Time expires
LED - Flashes Red for AR Time
OUTPUT - Relay held for duration of AR Time

INTRUSION OPERATION

ARMED STATE

 - Red LED

DOOR Opened by invalid entry
LED - Flashes Red
AUDIBLE - Constant tone, Auto Reset (AR) Timer begins
OUTPUT - Intrusion/Tamper Alarm relay toggles

- DOOR CLOSED

  LED - Flashes for duration of AR Time
  AUDIBLE - Continues for duration of AR Time
  OUTPUT - Changed for duration of AR Time

- REARM

 - After AR time expires OR by Manual reset

  LED - Red (Armed State)

TAMPER OPERATION

 (CX-DA401 only)

ARMED STATE

 - Red LED (Door Supervision Enabled)

- TAMPER

  (Door circuit open/shorted, or if unit is  

  removed from wall)
  LED - Flashing Red
  AUDIBLE - Constant tone
  OUTPUT - Intrusion/Tamper Alarm relay toggles

- RESET -

 Door normal, and Tamper switch closed   

  LED - Red (Armed State)

Reviews: