CX-EPD1289L Electric Preload RIM Strike

INSTALLATION INSTRUCTIONS

Page 2 of 7

Introduction 

RIM electric strikes, used with Pullman latch devices 

(i.e. exit devices) are very different from installing an electric 

strike for cylindrical or mortise lock sets, and therefore require 

additional considerations and a different installation technique.

Camden CX-EPD1289L is designed to provide up to 15 lbs of 

preload on the strike keepers. This unique feature eliminates 

typical installation challenges caused by warped or misaligned 

doors, frames or locking hardware.

4. INSTALLATION

Step 1: Using the Install Jig

Align template edge

 

with 

the jamb edge

(

Note :

 While aligning the 

template with the Jamb 

edge, If the door keeper 

does not align with the 

template cavity, Adjust the 

template)

 

Note:

1. Open door slightly. Place template on door jamb

aligning templates edge with jamb edge.

Note:

1. Open door slightly,

and remove the template.

Note:

1.

Close door making sure template is in place.

Align Crash bar latch with template latch hole.

2.

Mark holes center on the frame with a pencil or marker

3. While aligning the template with the Jamb edge, If the

door keeper does not align with the template cavity,

Adjust the template

Note:

1.

Use a hole punch on marked positions.

2.

Use drill size 5/8” to drill hole B

.

3.

Dril

l and tap holes A for 1/4-20x1-1/4" screws.

Marker/

Pencil

Closed

Door

Door Jamb

Crash

Bar

Marker/

Pencil

Jamb

Jamb

Hole punch 

Hole punch 

Ø

5

8

''

Ø

5

8

''

3

8

''

43

16

''

43

16

''

158''

Connecting

wire hole

Connecting

wire hole

Holes for

self-tapping

screws

A

A

B

1

2

5

4

3

Summary of Contents for CX-EPD1289L

Page 1: ...15lbs Endurance 1 000 000 Cycles Factory Tested 250 000 Cycles UL Verified Latch Projection 3 4 Fire Rating UL 10C CAN4 S104 3 hrs Fail Secure Only Mode Field Selectable Fail Safe Fail Secure Mechanic...

Page 2: ...te with the Jamb edge If the door keeper does not align with the template cavity Adjust the template Note 1 Open door slightly Place template on door jamb aligning templates edge with jamb edge Note 1...

Page 3: ...strike and mark the remaining 2 middle mounting screw positions on frame 5 Open the door and remove the strike from the frame drill and thread the 2 middle mounting screw holes for the 1 4 20 x 1 1 4...

Page 4: ...input wires Door Status Sensor Closed Position White N O Orange COM Grey N C Red Green Black Blue 12V 24V Black Red Blue Green 12V Varistor 24V Varistor Orange White Grey Black Red 12V 24V Blue Green...

Page 5: ...e type Fail Secure Type Fail Safe Type Step 4 Setting Fail Secure Fail Safe How to modify fail secure to fail safe or vice versa 1 Remove the cover plate Remove the 6 screws at the front of the electr...

Page 6: ...common reason for a strike failing Position the RIM strike so that the strike jaws lightly rest against the latch of the exit device Check that the door is not binding on the frame An electric strike...

Page 7: ...adlocking latch as shown here If exit device has a deadlocking latch the CX EPD1289L RIM strike must be mounted so that the deadlocking latch does not enter the latch cavity of the RIM strike Position...