 Installation Instructions 

 

 

 

 

 

 

First,  enter  program  mode.  Then  enter  [*6],  then  3#, 
then 0 to disable, or 1 to enable, then *. 
 
For example, 

[*6] 3 # 0 * 

will disable the audio tone on 

incorrect code entry. 

 
Request to Exit Audio Enable/ 
Disable - Function 5# 
 

Default: 0 (Disabled) 
Enable  or  disable  audio  annunciation  for  Channel  #1 
when a Request to Exit signal is input. When enabled, 
if  Channel  1  is  triggered  by  REX  input,  a  looped  tone 
(do-ray) will be annunciated for the duration that Relay 
#1  is  energized.  In  the  case  of  Toggled  mode,  the 
annunciation will last for 8 seconds (hard-coded). In the 
case  of  entering  into  Unlocked  Mode  (REX  input held 
for more than 15 seconds), 4 beeps will sound after the 
looped two-tone annunciation. A si

ngle (“Ray-Do”) tone 

will sound when exiting Unlock Mode. 
0 = disabled 
1 = enabled 
 
To enable/disable REX Audio Annunciation: 
First,  enter  program  mode.  Then  enter  [*6],  then  5#, 
then 0 to disable, or 1 to enable, then *. 
For  example, 

[*6]  5  #  1  * 

will  enable  the  audio 

annunciation for REX input. 

 
FACTORY DEFAULT SETTINGS 
 

If the settings have not been changed after shipment, 
or if they have been reset, they are as follows: 

Master User # 1 - Code is 1234. 

Main Channel = 3 sec 

Secondary Channel = programmable. 

Yellow LED enabled. 

 
 

Reset to Factory Defaults 
 

Reset the Master Code: 

While holding the # and * down together for 
aprox. 4 secs, power up the keypad.  There will 
be 4 beeps and all LED’s will flash.  The keypad 
will immediately move into the battery life 
indicator.  It will beep up to 5 times and the green 
LED will flash. 

Reset the keypad to factory defaults: 

While  holding  down  the  #  and  *  for  approx.  10 
seconds. Power up the keypad.  There will be the 

initial 4 beeps at the 4 second point, indicating the 
Master  Code  is  reset    (1234),  followed  by  the 
battery  test  beeps  (up  to  5),  then  followed  by  8 
beeps  indicating  the  keypad  has  been  reset  to 
factory defaults.

 

 

[*9] Erase Keypad Memory/Reset ALL to 
Factory 
 

Force factory default settings (use with caution) 
This is used when most or all of the programming has 
to be changed, as when a keypad has been moved to a 
new location. To reset to factory defaults. 
First,  enter  program  mode.  Then  enter  [*9],  then  re-
enter the master keycode, then *. 
 
For  example, 

[*9]  1  2  3  4  * 

will  immediately  and 

permanently  clear  the  entire  memory  (assuming  the 
master keycode has not been changed from the factory 
default. Once this function has been executed, there is 
NO WAY to restore the previous 

state. 

 

Section 4 _________________ 

 

Technical Data 

 

Model    

 

CM-120TX 

 

Illumination  

 

     No   /   Yes 

Size  

 

 

2 ¾” x 4 ½” x ¾” 
69.85mm x 114.30mm x 
19.05mm 

Mounting  

 

2 x #6-32 machine security 
screws 

Temperature  

 

-40° - +185°F (-40° - +85°C) 

Operating voltage  

2 x AA Alkaline Batteries 

Battery Life  

 

90,000 Operations 

 

 

 

Based on a 4 digit user code 

Capacity  

 

999 User codes 

Length  

Up to 8 digits (10 million 
possible codes) 

Response time   

0.3 seconds 

Inputs    

 

1 x REX input 
1 x Door Contact input 

Output    

 

RF Only, 2 Channels 
Channel 1 assigned to users 
1 - 499 
Channel 2 assigned to users 
500 - 999 

 
 

 
 

Summary of Contents for CM-120TX

Page 1: ...o terminal 2 Insert the batteries into the battery holder as shown in Figure 1 Figure 1 CM 120TX Power Connections Section 3__________________ How to Program Keypad Using This Manual Brackets and spac...

Page 2: ...TE A slow flash is once every two seconds and a fast flash is once every second GREEN LED ON Solid No errors output is active FAST FLASHING Keypad is in programming mode RED LED ON Solid Error conditi...

Page 3: ...abled For example 1 3 0 will disable Force Unique User Codes Backlight Control Enable Disable Function 5 Default 0 disabled Enable or disable backlight control on keypress When enabled the backlight w...

Page 4: ...ay time in seconds 0 disabled then For example 3 2 30 will set the door open alarm delay to 30 seconds NOTE To turn this feature on off see section 4 3 Door Prop Open Alarm on the next page 4 Alarm Co...

Page 5: ...usly until reset 6 Annunciation Control Functions Yellow LED Enable Function 0 Default 1 Enabled Enable or disable the yellow LED When enabled the yellow LED illuminates when any key is pressed 0 disa...

Page 6: ...D s will flash The keypad will immediately move into the battery life indicator It will beep up to 5 times and the green LED will flash Reset the keypad to factory defaults While holding down the and...

Page 7: ...mand memory will be cleared automatically Start again You will not increment the error count o The Lockout on errors feature is disabled by default This will prevent the keypad from hanging up if anyo...

Page 8: ...Installation Instructions 8...

Reviews: