background image

 Installation Instructions 

 

 

 

 

 

 

(User codes shorter than the maximum are still allowed, 
but  the  user  must  terminate  it  with  the 

current “enter” 

key). 
 
For example, 

[*1] 1 # 4 * 

will set all user codes to 

a fixed 4-digit length. 
 

Set Enter Key - Function 0# 
 

Default: ‘

*

’ 

If the code length has been left at 0 (see above), then 
use  this  feature  to  select  the  “enter”  key  used  to 
terminate user code entry. The default 

setting is ‘

*

’, but 

it  can  be  changed  to  any  key  on  the  keypad  (select 
carefully). 
 
For example, 

[*1] 0 # # * 

will change the user 

code 

enter key 

to ‘#’.

 

 
Incorrect Code Count Alarm - Function 2# 
 

Default: 0 (disabled) 
When set to zero, the keypad will not alarm on entry of 
invalid codes. When set to a value between 1 and 20, 
the  keypad  will  generate  an  alarm  after  the  specified 
number of invalid codes have been entered, within two 
minutes. 
 
For example, 

[*1] 2 # 6 * 

will set the keypad to generate 

an alarm when 6 invalid user codes have been entered. 
NOTE:  This  setting  also  requires  the  “Incorrect  code 
alarm Lockout” feature enabled. See 

5#

 on page 4. 

 

Force Unique User Codes - Function 3# 
 

Default: 1 (Enabled) 
When set to zero, the keypad will accept any user code 
for each user. When set to one, during programming of 
new user codes, the keypad will check the desired code 
against  all  currently  programmed  users,  and  only 
accept  the  user  code  if  it  is  unique.  Attempting  to 
program  a  code  that  is  not  unique  will  cause  an  error 
alarm,  and  the  programming  procedure  must  be 
restarted and a different code selected. 
 
NOTE:  When  enabling  this  mode  (when  previously 
disabled), it is recommended the administrator erase all 
settings back to factory defaults 

first

, to ensure all user 

codes  are  unique.  Failure  to  perform  this  step  may 
leave  duplicate  user  codes  among  those  already 
learned, and result in unexpected operation. 
0 = disabled 
1 = enabled 
For example, 

[*1] 3 # 0 * 

will dis

able “Force Unique User 

C

odes”. 

 

Backlight Control Enable/ Disable -
Function 5# 

 

Default: 0 (disabled) 
Enable or disable backlight control on keypress. 
When enabled, the backlight will be OFF until the first 
keypress. It will remain on for 5 seconds after the last 
keypress.  When  disabled,  the  backlight  will  remain 
OFF. 
0 = disabled 
1 = enabled 
To enable/disable Backlight Control mode: 
First,  enter  program  mode.  Then  enter  [*1],  then  5#, 
then 0 to disable, or 1 to enable, then *. 
For example, 

[*1] 5 # 1 * 

will make the backlighting turn 

ON  after  the  first  key  press.    The  backlighting  will 
remain ON for 5 seconds after the last key press. 
 

User Two “Global Lockout” - Function 6# 
 

Default: 1 (Enabled) 
When enabled, user #2 (a manager, for instance) can 
lockout all other users by prefixing his code by two (or 
more) “#” keys. When a global lockout is engaged, no 
user code will activate the outputs, except user #1 & #2. 
Programming functions, and request to exit (REX) are 
not  disabled.  This  can  be  used  (for  instance)  to 
immediately control all access while changing selected 
user codes in case of a security problem, or for lockout 
over a weekend. 
 
To disable user two “global lockout” feature: 
First,  enter  program  mode.  Then  enter  [*1],  then  6#, 
then 0 to disable, or 1 to enable, then *. 
0 = disabled 
1 = enabled 
For example 

[*1] 6 # 0 * 

will disable user #2’s ability to 

engage a global lockout. 

 
Note: 

When user number #2’s key code is prefixed with 

two or more ‘#’s, the “Global User Enable/ Disable” flag 
will be toggled. 

 

Channel Output Mode - Function 7# 
 

Default: 0 (Channel 1 Only) 
This  control  allows  the  installer  to  select  the  channel 
output mode. Chosing the default (0) means that a valid 
code activates Channel 1 only. 
Setting the Channel Output Mode to 

“1” will allocate the 

first 499 user numbers (memory addresses) to Channel 
1, and the remaining 500 user numbers to Channel 2. 
 
To choose the Relay Output mode: 
First,  enter  program  mode.  Then  enter  [*1],  then  7#, 
then 0 for Relay 1 only, 1 for split output, or 2 for both 
relays sequenced, then *. 

Summary of Contents for CM-120TX

Page 1: ...o terminal 2 Insert the batteries into the battery holder as shown in Figure 1 Figure 1 CM 120TX Power Connections Section 3__________________ How to Program Keypad Using This Manual Brackets and spac...

Page 2: ...TE A slow flash is once every two seconds and a fast flash is once every second GREEN LED ON Solid No errors output is active FAST FLASHING Keypad is in programming mode RED LED ON Solid Error conditi...

Page 3: ...abled For example 1 3 0 will disable Force Unique User Codes Backlight Control Enable Disable Function 5 Default 0 disabled Enable or disable backlight control on keypress When enabled the backlight w...

Page 4: ...ay time in seconds 0 disabled then For example 3 2 30 will set the door open alarm delay to 30 seconds NOTE To turn this feature on off see section 4 3 Door Prop Open Alarm on the next page 4 Alarm Co...

Page 5: ...usly until reset 6 Annunciation Control Functions Yellow LED Enable Function 0 Default 1 Enabled Enable or disable the yellow LED When enabled the yellow LED illuminates when any key is pressed 0 disa...

Page 6: ...D s will flash The keypad will immediately move into the battery life indicator It will beep up to 5 times and the green LED will flash Reset the keypad to factory defaults While holding down the and...

Page 7: ...mand memory will be cleared automatically Start again You will not increment the error count o The Lockout on errors feature is disabled by default This will prevent the keypad from hanging up if anyo...

Page 8: ...Installation Instructions 8...