Installation Instructions
5
To program how the “Door Prop open alarm” condition
is annunciated:
First, enter program mode. Then enter [*4], then 3#,
then the annunciation code, then *.
For example,
[*4] 3 # 1 *
will annunciate the buzzer
during the alarm.
NOTE 1:
this feature requires the use of the door
contact input.
NOTE 2:
The alarm will sound continuously until reset.
To reset, enter valid code.
NOTE 3:
To set Delay Time, see
[*3]
2# on Page 4.
Incorrect code alarm lockout - Function 5#
Default: 0 (Disabled)
Use to configure the incorrect code alarm lockout.
0 = disabled
1 = enabled
To program:
First, enter program mode. Then enter [*4], then 5#,
then the enable/disable code, then *.
For example,
[*4] 5 # 1 *
will configure the keypad to
lockout for 2 minutes (factory set lockout duration), after
the incorrect code count alarm limit is reached. During
the lockout period, all keypad entry (including correct
codes) is ignored.
There is an automatic reset after 2 minutes.
(See 2# on Page 3 of manual for setting code count)
Door Forced open Alarm - Function 6#
Default: 0 (Disabled)
Use to control how the “Door forced open alarm” is
annunciated.
0 = disabled
1 = buzzer
To program how the “Door forced open alarm” condition
is annunciated:
First, enter program mode. Then enter [*4], then 6#,
then the annunciation code, then *.
For example,
[*4] 6 # 1 *
will configure the keypad to
sound an alarm if the door is forced open (without
entering a valid code).
NOTE 1:
this feature requires the use of the door
contact input.
NOTE 2:
The alarm will sound continuously until reset.
[*6] Annunciation Control Functions
Yellow LED Enable - Function 0#
Default: 1 (Enabled)
Enable or disable the yellow LED. When enabled, the
yellow LED illuminates when any key is pressed.
0 = disabled
1 = enabled
To disable the yellow LED:
First, enter program mode. Then enter [*6], then 0 #,
then 0 to disable, or 1 to enable, then *.
For example,
[*6] 0 # 0 *
will disable yellow LED
illumination.
Buzzer Enable / Disable - Function 1#
Default: 1 (Enabled)
Enable or disable the buzzer. When disabled, the
buzzer will not sound for any condition
0 = disabled
1 = enabled
To disable the buzzer:
First, enter program mode. Then enter [*6], then 1#,
then 0 to disable, or 1 to enable, then *.
For example,
[*6] 1 # 0 *
will disable the buzzer for all
conditions.
Correct Code Audio Tone - Function 2#
Default: 0 (Disabled)
Enable or disable the audio tone annunciating correct
code entry. When enabled, a single 2 tone beep will
sound when a correct code has been entered. In the
case of toggled mode, the audio tone will last for 8
seconds (hard-coded) when a correct code toggles
relay one ON; the audio tone will be a single two-tone
beep, “do-ray”, when a correct code toggles relay one
OFF.
0 = disabled
1 = enabled
To enable the audio tone on correct code entry:
First, enter program mode. Then enter [*6], then 2#,
then (0 to disable, or 1 to enable), then *.
For example,
[*6] 2 # 1 *
will enable the audio tone on
correct code entry.
Incorrect Code Audio Tone - Function 3#
Default: 1 (Enabled)
Enable or disable the audio tone annunciating correct
code entry. When enabled, an audio tone will sound
when any incorrect code has been entered, for the
duration that the red LED is illuminated.
0 = disabled
1 = enabled
To disable the audio tone on incorrect code entry: