Grounding and lightning protection
ptp-450 (July 2014)
2-73
Figure 18
Grounding cable minimum bend radius and angle
Protection requirements for a mast or tower installation
If the BHM or BHS is to be mounted on a metal tower or mast, then in addition to the general protection
requirements (above), the following requirements must be observed:
The equipment must be lower than the top of the tower or its lightning air terminal.
The metal tower or mast must be correctly grounded.
A grounding kit must
be installed at the first point of contact between the drop cable and the tower, near the
top.
A grounding kit must be installed at the bottom of the tower, near the vertical to horizontal transition point.
This grounding kit must
be bonded to the tower or tower ground bus bar (TGB), if installed.
Schematic examples of mast or tower installations are shown in
Figure 19
Grounding and lightning protection on mast or tower