Analyzing the RF Environment
2-64
ptp-450 (July 2014)
Figure 15
OFDM
Frame Calculator tab
In the
Frame Calculator
tab, you can set the following parameters.
Table 39
OFDM Frame Calculator tab attributes
Attribute
Meaning
Link Mode
For BHM to BHS frame calculations, select
Multipoint Link
Platform Type BHM/BHM
Use the drop-down list to select the hardware series (board type) of the
BHM.
Platform Type BHS/BHS
Use the drop-down list to select the hardware series (board type) of the
BHS.
Channel Bandwidth
Set this to the channel bandwidth used in the BHM.
Cyclic Prefix
Set this to the cyclic prefix used in the BHM.
Max Range
Set to the same value as the
Max Range
parameter is set in the BHM(s).
Air Delay
This field should be left at the default of 0 ns.
Downlink Data
Initially set this parameter to the same value that the BHM has for its
Downlink Data
parameter (percentage). Then, as you use the Frame
Calculator tool in
, you will vary the value in this parameter to
find the proper value to write into the
Downlink Data
parameter of all
BHMs in the cluster.
PTP 450 Series BHMs offer a range of 15% to 85%, and default to 75%.
The value that you set in this parameter has the following interaction with
the value of the
Max Range
parameter (above):
The default
Max Range
value is 5 miles and, at that distance, the
maximum
Downlink Data
value (85% in PTP450) is functional.
Control Slots
Set this parameter to the value of the
Control Slot
parameter is set in the
BHMs.