phn-3967_005v000
Page 8-1
Chapter 8:
Specifications
Environmental Specifications for IDU
•
Operating: ETSI EN 300 019-1-3 Class 3.2
•
Temperature:
o
-5
C (23
F) to 55
C (131
F)
–
Temperature range for continuous operating temperature with
high reliability.
o
-25
C (-13
F) to 65
C (149
F)
–
Temperature range for exceptional temperatures, tested
successfully, with limited margins.
Note
Cold startup requires at least -5
C (23
F)
Humidity: 5%RH to 95%RH
Environmental Specifications for RFU
•
Operating: ETSI EN 300 019-1-4 Class 4.1
•
Temperature:
o
-33
C (-27
F) to +55
C (131
F)
–
Temperature range for continuous operating temperature
with high reliability:
o
-45
C (-49
F) to +60
C (140
F)
–
Temperature range for exceptional temperatures; tested
successfully, with limited margins:
•
Humidity: 5%RH to 100%RH
Mechanical Specifications
Table 12 IDU Mechanical Specifications
IDU Dimensions
Height: 44 mm/1.
73”
(1RU)
Width: 426 mm/16.77”
Depth: 180 mm
/7.08”
Weight: 2.5 kg/5.5 lbs.
IDU-RFU Connection
Coaxial cable RG-223 (300 ft), Belden 9914/RG-8
(1000 ft) or equivalent, TNC connectors to the IDU, N-