background image

Mounting  accessories

 

Yellow 

DATA Rx

 

Brown

 

VCC (Power +)

 

3.

 

Technical specifications 

(continuation) 

 

 

 

 

 

The Davis compatible ultrasonic wind sensor 
incorporates 12m of cable between the wind sensor 
and the box. 

 

50cm of cable terminated in RJ-11 comes out of the 
box. 

The wind sensor has been designed to avoid any 
mechanical parts to maximize reliability and 
minimize maintenance. 

 

The transducers communicate between themselves 
two by two using ultrasonic range waves. Each 
couple of transductors calculates the signal delay 
and gets information about both, wind direction and 
wind speed. 

The wind sensor has lateral and inferior female thread. It can be mounted either on a plate (inferior 

screws) or on a tube (lateral screws). 

 

North mark position

 

Make sure the north mark is perfectly aligned

 

 

 

 

M4x0,5 

M4x0,5

 

 

Inside the box there are two connectors, one where 
is connected the wind sensor and other where is 
connected the cable for the Davis Station. 

 

 

 

Pole mount up to 52 mm

 

 

 

Image 6. Wire connections. 

 

Davis compatible unit connections:

 

 

 

Aluminio and Carbon Fiber poles

 

 

 

Wind sensor connections:

 

 

 

 

The box can be attached to the pole with cable ties or similar. 

 

Davis Compatible

 

User manual

 

Davis Compatible

 

User manual

 

White 

GND (Power -) 

Green 

DATA Tx

 

3.11  Wind 

· Speed Range: 0-40 m/s 

information 

· Direction Range: 0-360 º 

3.8 Connections 

· Modular Connector (RJ-11) 

3.7 Attached cable

 

3.12 Easy mount

 

-

 

3 x M4 lateral female thread 

-

 

3 x M4 inferior female thread 

3.10 Sensors 

· Ultrasonic transducter (4x) 

· 2xAA, 3.6V Lithium primary 

batteries (duration 6 years) 

3.6 Power

 

Adapter to Poles up to 39mm

 

Flat mount

 

Yellow

 

VCC (Power +)

 

Green

 

WIND Direction

 

Red

 

GND (Power -)

 

Black 

WIND Speed 

3.9 Internal Connections

 