Manuale Uniflam Idro rev. 00
8
Position the stove at least 80 cm from flammable material, if this is not possible, a thermal protection
has to be done (UNI 7129, UNI 10683).
If the floor is made of flammable material (eg. parquet) it has to be used a plate of fireproof material
under and around the oven. The measure in front of the oven has to be at least the height from the
ground to the fire mouth + 30 cm, but not least then 60 cm. To the other sides it has to be the distance
from the floor to the fire mouth + 20 cm, but not least then 40 cm.
Make sure to install the oven in a surrounding where its function is not affected negatively.
Place the heater on the floor and ensure the correct position by using a standard spirit level.
Make sure that the sum of the volumes of heated rooms directly from the product and heated them
through hot water supply is not higher than calculated by us in the experimental phase.
WARNING: Not proper calculated needs of warming can lead to malfunction of the product and
dissatisfaction of the customer.
Indoor positioning
Our product, both in the AIR and the IDRO version, is a heater that draws air that is necessary for its
combustion process directly from the environment to be heated.
For this reason and for the even more important reason of safety for the people using it, the heater
must be installed in a sufficiently ventilated place in order to guarantee a continuous flow of air at all
times.
It is therefore essential to make air vents connected to the outside. See example in figure 2.1
Figure 2.1:
Example of making an air vent.
Detail A