48 HYDRA2
Installation Manual
Fixed Format I/O
GPoutputs
Relays are used for GP outputs. All 3
relay contacts are made available on the
GP output connector to provide flexibility
in use—they can be wired to produce
a standard closure when activated, to
produce a default closure that becomes
open when active, or to pass a ground
or voltage that is made or broken when
activated. Having all 3 contacts also
allows audio or other signals to be fed
through the relay and switched by GPIO
control if required. The Common pin is
always connected to one of the other
two pins by the relay—when the relay is
NOT activated, Common is connected to
the Normally Made pin. When the relay
becomes active (the assigned GP function
is triggered), the Common pin becomes
connected to the Normally Open pin. To
create a dry closure, Some typical wiring
examples are shown on this page.
GP OUTPUT WIRING EXAMPLE #1
GP OUTPUT WIRING EXAMPLE #2
GPinputs
Opto-isolated inputs allow for mixing
console functions to be triggered remotely
by other equipment. Applying voltage
across the + and - pins of an opto will
trigger it. If using a dry (no voltage) closure
as a trigger, one side of the closure should
be wired to one of the opto’s pins, the
other side of the closure should be wired
to ground, and the other side of the opto
should be wired to +ve voltage. Both
voltage and ground should be sourced
from the GPIO card itself where possible.
If the 3rd party kit sends a single logic
line, as opposed to a closure pair, both
pieces of equipment will need to share the
same ground reference, or +ve voltage
will need to be supplied by the 3rd party
kit. Common wiring examples are shown
on this page.
GP INPUT WIRING EXAMPLE #1
• In this example, the 3rd party
equipment provides a dry
closure. Voltage and ground are
supplied by the GPIO card
• In this example, the 3rd party
equipment provides a single
tally line which is grounded on
activation. Voltage is supplied
by the 3rd party. If voltage
is instead supplied by the
GPIO card, the two pieces of
equipment MUST have the
same ground reference.
• Wiring shown provides a dry-
closure on activation
• Wiring shown provides a
ground on activation. Note,
the ground is provided by the
device being triggered.
GP INPUT WIRING EXAMPLE #2
SW5739 GPIO COMPATIBILITY
I/O Type
GPIO
Compatible
AD5780
Yes
AD5781
Yes
AD5782
Yes
AE5732
Yes
AE5991
Yes
AE5992
Yes
JB5606
Yes
JB5783
Yes
JB5962
No
JM5736
No
JM5890
No
JM5831
No
Summary of Contents for Hydra2
Page 1: ...calrec com Putting Sound in the Picture HYDRA2 INSTALLATION MANUAL Gigabit Ethernet Networking...
Page 5: ...calrec com Putting Sound in the Picture HYDRA2 INFORMATION...
Page 9: ...calrec com Putting Sound in the Picture HYDRA2 ARCHITECTURE NETWORKING...
Page 28: ...28 HYDRA2 Installation Manual...
Page 29: ...calrec com Putting Sound in the Picture HYDRA2 CONNECTION INFORMATION...
Page 39: ...calrec com Putting Sound in the Picture HYDRA2 3RD PARTY REMOTE CONTROL...
Page 42: ...42 HYDRA2 Installation Manual...
Page 43: ...calrec com Putting Sound in the Picture HYDRA2 FIXED FORMAT I O...
Page 70: ...70 HYDRA2 Installation Manual...
Page 71: ...calrec com Putting Sound in the Picture HYDRA2 MODULAR I O...
Page 78: ...78 HYDRA2 Installation Manual...
Page 79: ...calrec com Putting Sound in the Picture HYDRA2 MODULAR I O CARDS...
Page 97: ...calrec com Putting Sound in the Picture HYDRA2 OBSOLETE MODULAR I O CARDS...
Page 99: ...calrec com Putting Sound in the Picture HYDRA2 SPECIFICATION...