24 HYDRA2
Installation Manual
Architecture & Networking
HYDRA2 CONNECTIONS AND REDUNDANCY
FIGURE 1 - CONNECTIONS FROM CORE TO IO BOX
CONTROL
ROUTER / EXPANDER
ENABLE
DSP
SYSTEM
RESETS
FAIL
GOOD
FANS
AES 3
VIDEO 2
VIDEO 1
WORD
CLOCK
SYNC INPUTS
DSP 1
PROCESSOR 1
PROCESSOR 2
DSP 2
PSU 1
PSU 2
CONTROL
EXPANSION 1
ROUTER 1
EXPANSION 2
ROUTER 2
POK
ST0
ST1
ST2
ST3
ST4
ST5
ST6
AC IN
USB
ST1
ST2
ST3
ST4
ST5
ST6
AC IN
USB
POK
ST0
ROUTER / EXPANDER
PSU
PSU
ROUTER / EXPANDER ROUTER / EXPANDER
DSP
DSP
ROUTER / EXPANDER
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
POK
MA
PRI
RST
MOK
NOK
ST1
ST2
D1
D2
D3
D4
D5
D6
D7
D8
D1
D2
D3
D4
D5
D6
D7
D8
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
9
11
13
15
10
12
14
16
1
3
5
7
2
4
6
8
10
9
12
11
14
13
16
15
2
1
4
3
6
5
8
7
ETHERNET
LINKS
LINKS
CONTROL PROCESSOR
MAC 6
MAC
4
MAC
3
MAC
5
USB
1
MOUSE
KBD
VGA
D1
D0
R1
R0
E1
E0
MA
POK
RST
PRI
NOK
MOK
ST2
ST1
LOW BATT
CF
USB
2
MAC 7
CONTROL PROCESSOR
MAC 6
MAC
4
MAC
3
MAC
5
USB
1
MOUSE
KBD
VGA
D1
D0
R1
R0
E1
E0
MA
POK
RST
PRI
NOK
MOK
ST2
ST1
LOW BATT
CF
USB
2
MAC 7
AC IN 1
AC IN 2
WEST YORKS, HX7 8EZ, ENGLAND. TEL: +44 (0)1422 842159
www.calrec.com
DO NOT RESTRICT VENTILATION HOLES
WARNING - THIS APPARATUS MUST BE EARTHED
ENSURE ALL COVERS AND SCREWS ARE FITTED
MAX AMBIENT OPERATING TEMPERATURE 40°C
CALREC AUDIO LTD, NUTCLOUGH MILL, HEBDEN BRIDGE
HYDRA 12-4 ANALOG
!
MODEL: AD5782
SERIAL No:
NOTE:
THE INPUT CURRENT STATED IS THE
OPERATING MAXIMUM FOR AC IN 1 OR
AC IN 2. WHEN BOTH AC INPUTS ARE USED
THE INPUT CURRENT IS NOMINALLY SHARED.
INPUT RATING
100-240V AC
50/60Hz
~
ADDRESS
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
0
1
0
1
PORT 1
FIBRE
PORT 1
NOT USED
PORT 2
NOT USED
PORT 2
FIBRE
GP OUTPUTS 1-8
GP INPUTS 1-8
Each core is fitted with a primary/
normally active router card in slot
2, and a secondary/backup router
card in slot 7. In an 8U core, optional
expansion router cards can be fitted—
primary in slot 1, secondary in slot 8.
Hydra2Connectivity
All I/O boxes have a primary/normally
active port 1, and a secondary/backup
port 2.
Port 1 of each I/O box should connect to
one of the front panel primary router or
primary expansion router ports.
To provide redundancy, port 2 of each I/O
box should be connected to secondary
router / expansion cards in the same core
as the primary connection.
Redundancy is provided when connecting
cores together by fitting a normally active
link between the primary router in one
core to the primary router in the other
core, and a backup connection fitted
between the secondary router of one
core to the secondary router of the other.
Core-to-core connections should always
be made to the main primary / secondary
routers, not expansion cards.
All Hydra2 connections—on I/O boxes
and on router cards—are made via SFPs
(small format pluggable) modules. Please
refer to “SFP - Overview” on page 30
for information on connection types, pin-
outs and length limitations.
CoreRedundancy
Standard cores provide complete
redundancy by being fitted with a full
set of backup hardware—a secondary
router, Control Processor and PSU, as
well as expansion router and DSP card if
primaries of these are fitted.
Sophisticated hardware and software
status monitoring, along with highly
flexible comms and data routing allow
for secondary cards to quickly and
automatically take over from primaries if
problems are detected. During a hot-
swap situation, the minimum amount
of hardware required swaps over to the
secondary cards in order to minimize
disruption and to retain maximum
redundancy in the unlikely event of a
further failure.
Summary of Contents for Hydra2
Page 1: ...calrec com Putting Sound in the Picture HYDRA2 INSTALLATION MANUAL Gigabit Ethernet Networking...
Page 5: ...calrec com Putting Sound in the Picture HYDRA2 INFORMATION...
Page 9: ...calrec com Putting Sound in the Picture HYDRA2 ARCHITECTURE NETWORKING...
Page 28: ...28 HYDRA2 Installation Manual...
Page 29: ...calrec com Putting Sound in the Picture HYDRA2 CONNECTION INFORMATION...
Page 39: ...calrec com Putting Sound in the Picture HYDRA2 3RD PARTY REMOTE CONTROL...
Page 42: ...42 HYDRA2 Installation Manual...
Page 43: ...calrec com Putting Sound in the Picture HYDRA2 FIXED FORMAT I O...
Page 70: ...70 HYDRA2 Installation Manual...
Page 71: ...calrec com Putting Sound in the Picture HYDRA2 MODULAR I O...
Page 78: ...78 HYDRA2 Installation Manual...
Page 79: ...calrec com Putting Sound in the Picture HYDRA2 MODULAR I O CARDS...
Page 97: ...calrec com Putting Sound in the Picture HYDRA2 OBSOLETE MODULAR I O CARDS...
Page 99: ...calrec com Putting Sound in the Picture HYDRA2 SPECIFICATION...