POWER/ENVIRONMENTAL SPECIFICATION
CONTROL SURFACE
Power
The console has two IEC AC power inlets feeding two sets of internal power distribution for each
set of 4 sections. Although the console will operate with one inlet supply per 4 sections, we
recommend both inlets are powered. This will ensure continued operation should a PSU or AC
source fail.
The operating AC supply voltage is 100V–240V +/-10%.
The inrush current is actively limited to 13A peak at 230V (6.5A at 115V) per 4 x internal PSU.
This much reduces the chance of a nuisance trip or fuse blow from a hot start after a momentary
brownout or blackout of the AC power. The total peak inrush current and quiescent current can
be specified for any size of console. There is a peak operating current when the motorised faders
move. The worst case is if all the faders move end to end where the peak power will be 4 Watts per
fader for <120ms.
Active PFC (Power Factor Correction) is employed in the power supplies and the PF (Power
Factor)
is typically greater than 0.88 dependant on console size.
The power measurements for 4 sections, 3 sections, 2 sections & 1 section are shown below.
Heat Output & Efficiency
The Heat output from the console is typically 0.9 times the RMS VA (Volts x Amperes).
These figures can be provided for any size of console.
The PSU efficiency under all operating conditions is typically greater than 85%, dependant on
console size.
Cooling
The control surface is cooled by natural air convection. The air intake is on the underside of the
console and the outtake is along the top rear of the console. At least 50mm (2') clearance must
be maintained for these vents.
Operating Ambient Air
Temperature
Short Term: 5°C - 35°C
Long Term: 15°C - 30°C
Relative Humidity
5% – 80% Non-condensing
ARGO CONSOLE PER-SECTION POWER MEASUREMENTS
VAC
(V)
Volt
AC (RMS)
(V)
Steady
State RMS
Current
(A)
* Worst
Case RMS
Current
(A)
Volt AC
(Plug-in
adapter)
(V)
Current
(Plug-in
adapter)
(A)
Power Factor
(Plug-in
adapter)
(%)
Power
(Plug-in
adapter)
(W)
Power Max
(Plug-in
adapter)
(W)
240
237.3
1.420
1.650
239
2.81
54
363
459
115
115.1
1.642
2.300
100
101.3
1.858
2.600
4-Section Power Measurements
Mains Measurements below were taken at wall socket
with Plug-in Power measurement Adapter (NB:240V only)
* All faders moving at once
Summary of Contents for ARGO
Page 1: ...calrec com ARGO INSTALLATION TECHNICAL MANUAL Digital Broadcast IP Production Console...
Page 5: ...calrec com ARGO INFORMATION...
Page 9: ...calrec com ARGO CONTROL SURFACES...
Page 15: ...15 FIG 7 FLOOR STAND FITTED CASTORS END ELEVATION ARGO Q...
Page 25: ...calrec com ARGO IMPULSE PROCESSING CORE...
Page 32: ...32 ARGO Digital Broadcast IP Production Console...
Page 33: ...calrec com ARGO CONNECTION INFORMATION...
Page 54: ...54 ARGO Digital Broadcast IP Production Console...
Page 55: ...calrec com ARGO EXTERNAL CONTROL...
Page 58: ...58 ARGO Digital Broadcast IP Production Console External Control...
Page 59: ...calrec com ARGO CONFIGURATION SETUP...
Page 66: ...66 ARGO Digital Broadcast IP Production Console...
Page 67: ...calrec com ARGO PANEL OPTIONS...
Page 74: ...74 ARGO Digital Broadcast IP Production Console...
Page 75: ...calrec com ARGO SPECIFICATIONS...
Page 91: ...91 USER NOTES...