Disconnect all power before installing or servicing
the heater. Failure to do so could result in personal
injury and/or property damage. All maintenance
and installation should be done by qualified
personnel in compliance with local codes.
MAINTENANCE
Low megohm on heating elements with epoxy or
hermetic seals cannot be serviced in the field.
Typical resistance values when sealed are 1000
megohm or greater.
26.0
Check that all connections are tight.
27.0
If a thermostat is provided, verify that it is operating properly
by cycling it and verifying cutout.
28.0
Perform an IR test prior to energization and verify that levels
are acceptable 500,000 ohms.
29.0
For adequate operation, always maintain the circulation
heater with the minimum design flow conditions for which the
heater was designed.
30.0
Retorque all bolted fitting connections and all electrical
connections after 10 cycles.
31.0
Always maintain a minimum of 2" (51 mm) of liquid above
the heated portion of the element or element failure may result.
32.0
Heaters stored for prolonged periods may absorb moisture.
Using a 500VDC megger (insulation resistance tester) check the
value of the insulation resistance to ground for each circuit. Initial
readings of over 500,000 ohms to ground are normally acceptable.
Should lower readings be observed, check factory for instructions.
33.0
Periodically check electrical connections for tightness and
check wire insulation for any damage and replace if necessary.
34.0
Remove the immersion heater periodically to inspect for
corrosion, sludge build-up and for scale removal. Discontinue use
if the heater shows signs of damage.
Note, the orientation of the flange or pipe plug relative to the vessel
before removal. Use a reference mark on the immersion heater
and vessel or draw a quick sketch showing the conduit connection
orientation, to ensure the proper orientation when re-installing.
35.0
Periodically check for leaks and torque of all bolted
connections.
Overtemperature devices in the heating bundles
are specifically located based on process and
heater design. Rotation of the bundles should be
avoided without consulting the manufacturer.
36.0
If a heater element is damaged (sheath rupture or electrical),
user must consult factory for further advice.
37.0
Heater output can be verified by loop current draw or
resistance check. If heater is not operating properly, user must
verify resistance, IR resistance to check integrity of heater
elements.
38.0
All returning product to the factory must be totally clean and
a copy of the MSDS of the process fluid/gas must accompany the
product.
CCI Thermal Technologies Inc. warrants to the purchaser of each new product that any part thereof which proves to be defective in
material or workmanship under normal use within 18 months of the date of shipment or 12 months from the date of start of operation
(whichever occurs first) will be repaired or replaced without charge. Any such defect should be brought to the attention of the company’s
office from which the product was purchased, which is authorized to furnish or replacement within the terms of this warranty.
The Company will not be responsible for any expenses incurred in installation, removal from service, transportation cost, or damages of
any type whatsoever, including incidental or consequential damages.
Since we cannot anticipate or control the condition under which our products may be used, we accept no responsibility for the safety and
suitability of our products when used alone or in combination with other products. Tests for safety and suitability of the products should
be done by the user.
This warranty will not apply if, in the judgement of the Company damage or failure has resulted from accident, alteration, misuse, abuse
or operation on an incorrect power supply. The foregoing is in lieu of other warranties expressed or implied. CCI Thermal Technologies
Inc. neither assumes no authorizes any person to assume for it any other obligation, during transportation, installation and operation or
liability in connection with the said product.
Since the paint finish may be damaged in use, no warranty applies to such paint finish except for manufacturing defects which become
apparent within 30 days from date of installation.
Heaters are not guaranteed against damage caused by corrosion.
MAINTENANCE