Page 24
Calorex Heat Pumps Ltd. · The Causeway, Maldon, Essex CM9 4XD, UK
Technical Manual
PPT8/12/16/22LX/LY SLIMLINE
SD638160 ISSUE 22d
®
MODEL
Units
PPT8
PPT12
PPT16
PPT22
HEAT TO POOL WATER
AMBIENT 10°C, WATER 24°C
kWh
7.2
9.9
12.4
17.7
AMBIENT 20°C, WATER 24°C
kWh
9.2
12.5
15.6
22.4
ELECTRICITY
ELECTRICAL SUPPLY 1 PHASE
ELECTRICAL SUPPLY 3 PHASE
TOTAL POWER CONSUMED
AMBIENT 10°C, WATER 24°C
kWh
1.8
2.3
2.6
4.1
AMBIENT 20°C, WATER 24°C
kWh
2.0
2.5
2.8
4.3
MIN SUPPLY CAPACITY (Max F.L.A.) 1 ph N:-
A
14.0
17.0
19.8
31.0
MIN SUPPLY CAPACITY (Max F.L.A.) 3 ph N:-
A
6.0
6.4
8.0
13.0
RECOMMENDED SUPPLY FUSE 1 ph N:-
A
20.0
25.0
30.0
42.0
RECOMMENDED SUPPLY FUSE 3 ph N:-
A
10.0
10.0
15.0
20.0
WATER FLOWS ETC
POOL WATER FLOW RATE:-
L/min
75
75
125
167
POOL WATER PRESSURE DROP (@ Rated Flow):-
m hd
0.1
0.1
0.1
0.6
MAX WORKING PRESSURE POOL WATER:-
bar
2.5
2.5
3.5
3.5
POOL WATER CONNECTIONS:-
inches
CONDENSATE DRAIN CONNECTIONS:-
inches
COMPRESSOR
NOMINAL POWER CONSUMED
kWh
1.6
2.35
2.6
3.8
L.R.A. 1 ph N:-
A
62
62
103
136
R.L.A. 1 ph N:-
A
11.5
13.1
15.8
25
SOFT START AMPS 1 ph N:-
A
28
28
34
37
L.R.A. 3 ph N:-
A
32
30
48
48
R.L.A. 3 ph N:-
A
4
4.7
7.3
10
SOFT START AMPS 3 ph N:-
A
14
14
25
25
MAIN FAN
AIR FLOW (Anemometer @ air on grille. Dry evaporator):-
m³/h
2200
3300
3500
4100
F.L.A. 1 ph N:-
A
0.82
0.82
0.82
0.82
GENERAL DATA
HERMETIC SYSTEM
GAS CHARGE R407c
kg
1.9
2.5
5.0
6.0
SOUND PRESSURE LEVEL @3m AIR ON
dbA
53
54
53
54
SOUND PRESSURE LEVEL @3m AIR OFF
dbA
57
55
55
56
SOUND PRESSURE LEVEL @3m SIDE
dbA
50
47
48
52
SOUND POWER
dbA
69.9
67.3
68.2
67.8
*PHYSICAL DIMENSIONS
*WIDTH (Unpacked):-
mm
1264
1264
1264
1264
*DEPTH (Unpacked):-
mm
594
594
600
600
*HEIGHT (Unpacked):-
mm
725
725
725
904
WEIGHT (Unpacked):- ALX
kg
91
96
113
119
WEIGHT (Unpacked):- BLX
kg
-
96
118
119
WEIGHT (Packed):- ALX
kg
110
119
142
143
WEIGHT (Packed):- BLX
kg
110
119
140
143
FOR ACCURATE APPLICATION SIZING CONSULT CALOREX HEAT PUMPS LTD
400V/~3N/ 50Hz
1 1/2" or 50mm Female
3/4" DOMESTIC WASTE
230V/~1N/ 50Hz
NOTES
1) Weight and dimensions nett. * DIMENSIONS INCLUDE WATER IN/OUT STUBS AND MAINS IN CABLE GLAND.
2) Performance design limitations: Ambient = 5ºC min 40ºC max, Water = 10ºC min, 40ºC max.
3) Pool water to have correct balance, pH 7.2-7.8, Free Chlorine 1.0 - 2.0ppm domestic, 3.0 - 6.0 commercial.
4) Allow 500mm clearance to service panels.
5) Calorex reserve the right to change or modify models without prior notice.
6) R407c Global warming potential (GWP) 1700.
1mm WG = 9.8 Pa