Page 115
Calorex Heat Pumps Ltd. · The Causeway, Maldon, Essex CM9 4XD, UK
Technical Manual
PPT8/12/16/22LX/LY SLIMLINE
SD638160 ISSUE 22d
®
Parameter
Name
GROUP כ o. (RELATIVE TO CONFIGURATION OF OUTPUTS & BUZZER )
OUT1 FUNCTION
oF = NO FUNCTION
Co = COMPRESSOR
rc = HOT GAS REVERSE CYCLE
Fn = FAN NOT IN PARALLEL WITH COMPRESSOR (OFF DURING DEFROST)
Fd = FAN NOT IN PARALLEL WITH COMPRESSOR (ON DURING DEFROST)
FP = FAN IN PARALLEL WITH COMPRESSOR (OFF DURING DEFROST)
FH = FAN IN PARALLEL WITH COMPRESSOR (ON DURING DEFROST)
Pu = PUMP
At / -t= SILENCEABLE ALARM
AL / -L = NON SILENCEABLE ALARM
on = ON WHEN INSTRUMENT SWITCHES ON
o.o2
OUT2 FUNCTION: see “o.o1”
Pu
o.o3
OUT3 FUNCTION: see “o.o1”
Co
o.o4
OUT4 FUNCTION : see “o.o1”
rc
BUZZER FUNCTION MODE
oF = DISABLE
1 = ACTIVE ALARMS ONLY
2 = KEY PRESSED ONLY
3 = ACTIVE ALARMS & KEY PRESSED
GROUP כ t. (RELATIVE TO KEYBOARD CONFIGURATION)
FUNCTION MODE KEY U:
oF= NO FUNCTION
1= ACTIVE SELECTION OF SET POINT (SP/SP2)
2= SWITCH ON/OFF (STAND-BY)
t.Fb
FUNCTION MODE KEY DOWN/AUX: see “t.UF”
oF
t.Lo
KEYBOAD LOCK FUNCTION DELAY
oF
t.SA
ACTIVE SET POINT
1
r.Pn
PUMP RUN SAMPLING TIME
3.00
r.Pf
PUMP ON DAMPLING TIME DELAY
60.0
P.P1
COMPRESSOR START UP TIME DELAY
6.00
Description
Setting
PARAMETERS VISIBLE USING PASSWORD -181
o.o1
Fn
t.UF
oF
o.bu
2
For error codes associated with the thermostat see section 8.1 “User Check List”.