12.0 WARRANTY CONDITIONS
The following exclusions apply to the Warranty given by Dantherm Ltd. No
claims will be accepted if :
1. The heat pump is incorrectly sized for the application.
2. The heat pump is installed in any way that is not in accordance with the
current procedures as defined by Dantherm Ltd.
3. The heat pump has been worked upon or is adjusted by anyone other
than a person authorised to do so by Dantherm Ltd.
4. The air flow to and from the machine is outside the specified limits.
5. The water flow through the machine is outside the specified limits.
6. The water pH level and/or chemical balance is outside the following limits:
7. The heat pump has suffered frost damage.
8. The electrical supply is insufficient or in any way incorrect.
9. The fan amps and duct pressure are outside the specified limits.
10. The heat pump has not been maintained in accordance with service
requirements in section 4.1.
If in doubt or if advice is required please contact the Dantherm Group
UK Service Department by calling 01621 856 611
or emailing [email protected]
Note:
The Reply Paid Warranty Registration Card must be returned, to ensure
that the correct warranty is given. If you do not find a Registration Card with
your heat pump please contact the Dantherm Group UK Service Department
giving your name, address and serial number of your heat pump. A card will be
sent to you for completion.
Please give
MODEL NUMBER
and
SERIAL NUMBER
of your heat pump when
making technical or service enquiries. This will assist in correct diagnosis and
ensure service can be provided with the minimum delay.
Acidity pH
pH
7.2 - 7.8
Total Alkalinity, as CaCO3
ppm
80 - 120
Total Hardness, as CaCO3
ppm
150 - 250
Total Dissolved Solids
ppm
1000
Maximum Salt Content
ppm
35000
Free Chlorine Range
ppm
1 - 2 Domestic
Free Chlorine Range
ppm
3 - 6 Commercial
Superchlorination
max
30ppm for 24 hrs
Bromine
ppm
2 - 5
Baquacil
ppm
25 - 50
Ozone
ppm
0.9 Max
Maximum Copper Content
ppm
1
Aquamatic Ionic Purifier
ppm
2 Max
25