NOTES
1) Weight and dimensions nett. * Dimensions
include
water in/out stubs and mains in cable gland.
2) Performance design limitations: Ambient = 5°C min 40°C max, Water = 10°C min, 40°C max.
3) Pool water to have correct balance, pH 7.2-7.8, Free Chlorine 1.0 - 2.0 ppm domestic, 3.0 - 6.0 commercial.
4) Allow 500mm clearance to service panels.
5) Dantherm Ltd. reserves the right to change or modify models without prior notice.
6) R134a Global warming potential (GWP) 1430.
1mm WG = 9.8 Pa
1mhd = 1.4 psi
1l/min = 0.22gall/min
9.0 DATASHEETS
HEATER CHILLERS-BHC
Model
Units
PPT16
PPT22
Heat to pool water
Heating mode
Heating
Ambient 20°C, 85% RH, water 28°C
Heating to water at 28°C
kW
13.0
19.0
Electrical input
kW
3.5
5.0
Cooling mode
Ambient 45°C, 50% RH, water 32°C
Cooling
Cooling of water from 32°C
kW
10.2
13
Electrical input
kW
4.1
5.5
Electricity
Electrical supply 3 phase
400V ~3N 50Hz
Total power consumed
Min supply capacity (Max F.L.A.) 3 ph N
A
10.3
12.9
Recommended supply fuse 3 ph N
A
15.0
20.0
Water
Pool water flow rate
L/min
123
123
Pool water pressure drop (at rated flow)
m hd
0.2
0.2
Max workibg pressure of pool water
bar
3.5
3.5
Pool water connections
inches
1½ or 50mm FEMALE
Condensate drain connections
inches
¾" DOMESTIC WASTE
Compressor
Nominal power consumed
kWh
2.6
3.8
L.R.A. 3 ph N
A
48
48
R.L.A. 3 ph N
A
7.3
10
Soft start amps 3 ph N
A
25
25
Main fan
Air flow (Anemometer at air on grille. dry evaporator)
m³/h
4000
5000
F.L.A. 1 ph N:-
A
0.82
1.75
General data
Hermetic system
Gas charge R134a
kg
8.0
8.7
Sound pressure level at 3m Air on
dbA
53
54
Sound pressure level at 3m Air off
dbA
55
56
Sound pressure level at 3m Side
dbA
48
52
Sound power
dbA
68.2
67.8
*PHYSICAL DIMENSIONS
*Width (Unpacked)
mm
1264
1264
*Depth (Unpacked)
mm
600
600
*Height (Unpacked)
mm
725
904
Weight (Unpacked) BHC
kg
131
145
For accurate application sizing consult Dantherm Ltd.
21
SD6381652 ISSUE 4