HEATER CHILLERS - BMCY
NOTES
1) Weight and dimensions nett. * Dimensions
include
water in/out stubs and mains in cable gland.
2) Performance design limitations: Ambient = 5°C min 40°C max, Water = 10°C min, 40°C max.
3) Pool water to have correct balance, pH 7.2-7.8, Free Chlorine 1.0 - 2.0 ppm domestic, 3.0 - 6.0 commercial.
4) Allow 500mm clearance to service panels.
5) Dantherm Ltd. reserves the right to change or modify models without prior notice.
6) R407c Global warming potential (GWP) 1774.
1mm WG = 9.8 Pa
1mhd = 1.4 psi
1l/min = 0.22gall/min
Model
Units
PPT16
Heat to pool water
Heating mode
Heating
Ambient 10°C, 85% RH, water 24°C
Heating to water at 24°C
kW
13.0
Electrical input
kW
3.25
Cooling mode
Ambient 30°C, 50% RH, water 24°C
Cooling
Coopling of water to 24°C
kW
10
Electrical input
kW
4.0
Electricity
Electrical supply three phase
400V~3N 50Hz
Total power consumed
Min supply capacity (Max F.L.A.) 3 ph N
A
9.6
Recommended supply fuse 3 ph N
A
16.0
Water
Pool water flow rate
L/min
123
Pool water pressure drop (at rated flow)
m hd
0.2
Max working pressure of pool water
bar
3.5
Pool water connections
inches
1½” or 50mm female
Condensate drain connection
inches
¾" Domestic waste
Compressor
Nominal power consumed
kWh
2.6
L.R.A. 3 ph N
A
48
R.L.A. 3 ph N
A
7.3
Soft start amps 3 ph N
A
25
Main fan
Air flow (Anemometer at air on grille, dry evaporator)
m³/h
4000
F.L.A. 1 ph N
A
0.82
General data
Hermetic system
Gas charge R407c
kg
5.9
Sound pressure level at 3m Air on
dbA
53
Sound pressure level at 3m Air off
dbA
55
Sound pressure level at 3m Side
dbA
48
Sound power
dbA
68.2
*Physical dimensions
*Width (Unpacked)
mm
1264
*Depth (Unpacked)
mm
600
*Height (Unpacked)
mm
725
Weight (Unpacked) BMCY
kg
135
22
SD638152 ISSUE 4