WIRING DIAGRAM PAC6500/ HEX22A [SERIES 3]

D355560 ISSUE 10

1

3

4

7

A

6

9

B

RELAY [K2]

D

EF

RO

ST

 S

T

AT

 [

F

T

]

(6 MINS)

DELAY TIMER [D2]

G

R

 0

.5

G

0

.5

G

0

.5

P 0

.5

O

 0

.5

O

 0

.5

0

.5

0

.5

R

/B

0.5

B

 0

.5

0.

5

R/BR 0.5

0.

5

B

 0.5

(5 MINS)

N

L

1

3

BUTTS

LOOM

4

5

6

1

2

3

4

5

6

1

2

3

3 POSN MODE

SWITCH [S1]

MAINS

DEFROST

CHILL

[CL]

[DL]

[RL]

2

4

1

3

CONTROL FUSE 7A

      [F1]

CONDENSATE FUSE 1A

       [F2]

E

L

N

SOCKET TO HEX 
UNIT

TERMINAL 
BOX

FLOAT SWITCH
HIGH LEVEL

FLOAT SWITCH

LOW LEVEL

SUMP

[FS1]

[FS2]

NOTE ORIENTATION OF SWITCHES

SOLENOID VALVE 
[Y]

DELAY TIMER [D1]

5

3

1

6

4

2

21

AUX

A1

22

N/C

A2

8 COM

7 N/C

6 N/O

5 FAULT SGNL

4 OUT

3 SIGNAL IN

2 L

1 N

4

7

A

6

9

B

S

EN

SO

R

1

2

3

4

5

6

7

8 9

12

DIGITAL AIR STAT 
[AT]

(TECNOLOGIC)

10 11

(HIGH)

  2 POSN

SWITCH [S2]

CONDENSATE PUMP

     [MP]

(FAN ONLY)

(COOL)

   
PUMP

CONTROLLER

CONTACTOR  [B]

RELAY [K1]

WATER 
PUMP

B 0.

5

B 1.5

B 0.5

B 0.5

B 1.5

1

.5

BR 1.5

BR 1.5

BR 1.5

BR

 0.5

R 0.5

BR 1.5

BR

 1.5

B

 0.5

0.

5

W/R 0.5

W

/R

 0

.5

W

/R

 0

.5

W

/R

 0.5

BR

 1.0

0.5

0.5

R/

BR

 0

.5

W

/R

 0

.5

G

/R

 0.5

G

/R

 0

.5

W

 0

.5

G

0

.5

B

 0.5

R 0.5

0

.5

BR

 0.5

B

R

 0

.5

BR

 0.5

BR 0.5

BR 0.5

BR 0.5

P

 0

.5

P

 0

.5

0.5

O

/B

L

 0

.5

R 0.5

R/

BL

 0

.5

W

/BL

 0.5

W

/B

L 0

.5

W

 0

.5

W 0.5

W

/B

L0

.5

W

/B

L0

.5

W

/BL0

.5

W

/B

L

0

.5

O 0.5

B

L

UE

B

L

UE

B

L

UE

0

.5

G

REY

G

REY

G

R

E

Y

G

RE

Y

FLY 
LEADS

B 0.5

B 0.5

0.5

B 0.5

B 0.5

B 0.5

B 0.5

BL 1.5

B 0.5

W 0.5

W 0.5

G/R 0.5

G/R 0.5

G/R 0.5

G/R 0.5

R/

BR

 0

.5

O 0.5

O 0.5

W/R 0.5

W 0.5

1

.0

BL

 1.0

R 1.0

BL 1.0

BR

 1

.0

B

1.0

BR 0.5

BR 0.5

R 1.5

B 0.5

BR 0.5

GREY

GREY

GREY

GREY

G/Y 
1.0

G

/Y

 1.0

G/Y 1.0

G/Y 1.0

G/Y 1.0

R/

0

.5

0.5

O

 0

.5

0

.5

B 0

.5

0

.5

G

0

.5

G

R

 0.5

B

L

UE

FLY 
LEADS

(LOW)

B

 0

.5

GR/B 0.5

 
BKT

EARTH

 
BKT

EARTH

G/Y 1.0

G

/Y

 1.0

B

 0

.5

B 0.5

B 0.5

BR 0.5

G/Y 1.0

L

L

N

N

COUPLING PLUG

10V

1

2

3

0V

FAN SPEED

CONTROLLER

[FSC]

R

/O

 0

,5

BL 

0,5

R

/B

L 0

,5

R

/B

 0

,5

O

 0,5

GR/B

O/BL

R/B

R/BL

R/BR

W/BL

W/R

GREY/BLUE

ORANGE/BLACK

RED/BLUE

RED/BLACK

RED/BROWN

WHITE/BLACK

WHITE/RED

GRAU/BLAU

GRIS/BLEU

ORANGE/SCHWARZ

ROT/BLAU

ROT/SCHWARZ

ROT/BRAUN

WEIB/SCHWARZ

WEIB/ROT

ORANGE/NOIR

ROUGE/BLEU

ROUGE/NOIR

ROUGE/MARRON

BLANC/NOIR

BLANC/ROUGE

G/R

GREEN/RED

GRUN/ROT

VERT/ROUGE

BL

B

BR

GR

O

P

R

W

G/Y

GREEN/YELLOW

WHITE

RED

PINK

ORANGE

GREY

BROWN

BLUE

BLACK

SCHWARZ

BLAU

BRAUN

GRAU

ORANGE

ROSA

ROT

WEIB

GRUN/GELB

NOIR

BLEU

MARRON

GRIS

ORANGE

ROSE

ROUGE

BLANC

VERT/JAUNE

V

VIOLET

VIOLETT

VIOLETTE

LOOM

HE

UN

IT

BLU

E

BR

O

WN

BLAC

K

Y

ELL

O

W

GR

E

EN

G

/Y

 1.

0

W

 0,

5

BR

 0,5

B

L 0,5


0,5

FAN 
MOTOR

C

AP

TB

PLUG

E

L

N

Summary of Contents for PORTATEMP 6500AX MKIII

Page 1: ...ISEUR MOBILE 2 POUR DECONNECTEUR L APPAREIL D UNE INSTALLATION DEBRANCHER LES RACCORDS RAPIDES D EAU SI POSES SUR LE CLIMATISEUR MOBILE D ABORD SEUL UN PERSONNEL QUALIFE FORME PAR CALOREX EST AUTORISE...

Page 2: ...Page 2...

Page 3: ...ically and horizontally and in conjunction with the fan speed control switch the air velocity and direction can be carefully set up to obtain maximum coverage of the area being cooled without causing...

Page 4: ...king or unnecessary restrictions to the flow of water inside Also remember that plastic and rubber becomes much more flexible when warm and as a result much more susceptible to distortion USE THE CHAI...

Page 5: ...ded that a mixture by volume of one part antifreeze to two parts water is utilised this will prevent freezing down to an external temperature of 20 C 5 F The approximate total volume of the PAC system...

Page 6: ...0 G Y 1 0 G Y 1 0 G Y 1 5 G Y 1 5 G Y 1 0 PIPE EARTH G Y 1 0 FLY LEADS G Y 1 0 TANK LP HP MAINS LEAD 2 3 G Y 1 0 G Y 1 0 O NC N L SUPPLY V IN GND Alarm Tacho NOT USED NOT USED SIGNAL O 0 5 R BR 0 5 R...

Page 7: ...R 0 5 R BL 0 5 W BL 0 5 W BL 0 5 W 0 5 W 0 5 W BL0 5 W BL0 5 W BL0 5 W BL0 5 O 0 5 BLUE BLUE BLUE P 0 5 GREY GREY GREY GREY FLY LEADS B 0 5 B 0 5 B 0 5 B 0 5 B 0 5 B 0 5 B 0 5 BL 1 5 B 0 5 W 0 5 W 0 5...

Page 8: ...ty red mains light will illuminate b Select Fan Only with the mode switch The fan will start c Select Fan Speed with the fan speed switch high or low depending on air velocity required d Select Coolin...

Page 9: ...is fitted to optional ducting The switch is situated in the electric box and is accessed by removing the upper back panel It needs to be set to the 3 position Use of the switch in this position 3 with...

Page 10: ...TALLATION LINESET FROM PAC THIS SIDE WALL WALL FIT FULL PLATE FIRST 265 75 4 HOLES DIA 6mm TOP BOTTOM INSIDE WALL OUTSIDE WALL TOP BOTTOM POSITION FOR A PADLOCK TO SECURE LID TO BOX IF DESIRED 35 The...

Page 11: ...plication and can only be determined by the user However you should never allow more than two months to elapse between cleaning The probable life of the filter will be about one year and spares are av...

Page 12: ...ENTION High Pres sure fault light illuminated High pressure trip Cure Press button to re set and check for Lack of water flow kinked hoses Shortage of water top up External heat exchanger unit mounted...

Page 13: ...E ALLOWED RANGE CHECK THE CONNECTION OF THE PROBE AND THE DIGITAL THERMOSTATAND THAT THE PROBE IS WORKING CORRECTLY EEPr INTERNAL MEMORY ERROR CHECK AND IF NECESSARY REPROGRAM THE PARAMETERS IN TECHNI...

Page 14: ...Page 14...

Page 15: ...roidir sans cr er de courants d air Il existe alternativement une autre possibilit de soufflage avec un double conduit de 18 cm de diam tre On doit particuli rement faire attention ne pas obstruer la...

Page 16: ...avant son arriv e sur le site Le raccord lectrique rapide 3 broches enfoncer avec la bague de blocage vissable et serrer la main uniquement et le raccord rapide pour le tuyau d vacuation du condens t...

Page 17: ...Page 17 BOUCHON DE REMPLISSAGE PORTATEMP 6500 FIG 2...

Page 18: ...0 G Y 1 0 G Y 1 0 G Y 1 5 G Y 1 5 G Y 1 0 PIPE EARTH G Y 1 0 FLY LEADS G Y 1 0 TANK LP HP MAINS LEAD 2 3 G Y 1 0 G Y 1 0 O NC N L SUPPLY V IN GND Alarm Tacho NOT USED NOT USED SIGNAL O 0 5 R BR 0 5 R...

Page 19: ...0 5 R BL 0 5 W BL 0 5 W BL 0 5 W 0 5 W 0 5 W BL0 5 W BL0 5 W BL0 5 W BL0 5 O 0 5 BLUE BLUE BLUE P 0 5 GREY GREY GREY GREY FLY LEADS B 0 5 B 0 5 B 0 5 B 0 5 B 0 5 B 0 5 B 0 5 BL 1 5 B 0 5 W 0 5 W 0 5 G...

Page 20: ...ermostat TLZ11 Cliquer une fois sur le bouton P L affichage SP Set Point et point de consigne 28 s afficheront alternativement Utiliser les fl ches ou pour changer la valeur d sir e Cliquer de nouveau...

Page 21: ...il est connect avec une gaine de soufflage Le commutateur est situ dans le boitier lectrique accessible en otant la partie sup rieure du panneau arri re Il doit est bascul sur la position 3 ATTENTION...

Page 22: ...sort pas du climatiseur Diagnostic Le voyant vert d ALIMENTATION MAINS est teint Rem de Allumer I lectricit et ou v rifier le fusible de l alimentation principale Probl me L air ne sort pas du climati...

Page 23: ...OU LIT UNE TEMPERATURE DEHORS DE LA PLAGE DE FONCTIONNEMENT VERIFIER LA CONNEXION DE LA SONDE ET SON ETAT DE FONCTIONNEMENT EEPr ERREUR DANS LA MEMOIRE INTERNE VERIFIER ET SI NECESSAIRE REPARAMETRER L...

Page 24: ...Page 24...

Reviews: