generator completely cools  down. Label  the three wires  which connect  the upper  part of the main 
board to the water level sensor and the source, drain pump, electromagnetic drain valve and water 
inlet  electromagnetic  valve  in  the  bottom  part  of  the  main  board.  Unplug  these  wires  and  remove 
the  main  board  (be  careful  with  yellow-green  ground  wire  under  the  screws  of  the  circuit  board). 
Install the replacement back carefully. 

6.

 

Replace  the  sub-board:

  switch  off  the  steam  generator  and  remove  the  service  shape  cover 

when  the  generator  completely  cools  down.  Unplug  all  the  wires  on  the  sub-board.  Label  all  the 
wires on the relay and remove the sub-board. Install the replacement back carefully. 

7.  Replace  the  electromagnetic  valve  and  drain  pump: 

switch  off  the  steam  generator  and 

disconnect  the  power  and  water  supply.  Remove  the  water  inlet  pipe,  drain  pipe  and  steam  outlet 
pipe when the generator completely cools down, then remove all pipes, wires and screws. 

8.  Replace  the  water  level  sensor:

  switch  off  the  steam  generator  and  remove  the  water  level 

sensor service cover on the equipment after the generator cools down. Special care should be taken 
to  the  plugs  of  the  water  level  sensor  corresponding  to  the  blue  wire  and  the  two  white  wires 
respectively.  Take  off  all  the  wires,  screw  out  the  water  level  sensor,  and  screw  in  the  new  water 
level  sensor  until  the  bottom  of  the  plastic  nut  reaches  the  same  height  as  the  old  one.  Finally 
reconnect  the blue wire and the two white wires  (the blue wire must be plugged back to  the right 
place). 

 

Cut off the power supply before any maintenance.

 

 

Test the equipment after maintenance. 

 

CHAPTER 5    TROUBLESHOOTING 

 

Repair  can  only  be  performed  by  qualified  professionals,  for  more  services  or  technical  helps 

please contact the dealer.   

NTC  model  steam  generator  has  self-diagnose  function,  and  some  common  faults  will  be 

displayed on the LCD if occur.   

 

Code 

Meaning 

Diagnose and Solution 

-

L

 

Temperature measured by temperature 
sensor is below 43

 

   

Check whether the room temperature is below 
43

,  the  code  should  disappear  after  the 

room  temperature  reaches    43

.  Otherwise 

check the connection of the sensor.     

-

H

 

Temperature measured by temperature 
sensor is higher than 140

 

Check whether the room temperature is above 
140

,  the  code  should  disappear  after  the 

room  temperature  drops  below  140

Otherwise check the connection of the sensor. 

-

E

 

Fault  on  the  water  supply,  heating 
elements stop working 

Check 

the 

connection 

and 

status 

of 

electromagnetic  valve,  water  supply

magnetizer  and    water  level  sensor.  After 
clean  or  replacement,  restart  the  system  and 
you should feel the flow of incoming water. 

Summary of Contents for NTC-60

Page 1: ...Calor de Hogar Av Tecnol gico 735 PB San Salvador Tizatlalli Metepec 52172 Edo de M xico Tel fono 722 216 3330 55 1163 6038 www calordehogar com servicio calordehogar om c ventas calordehogar com...

Page 2: ...Content 1 Introduction 2 Chapter 1 Parameters 3 Chapter 2 Installation and Cautions 5 Chapter 3 Functions and Operation 12 Chapter 4 Maintenance 14 Chapter 5 Troubleshooting 15 Chapter 6 Warranty and...

Page 3: ...ual for further reference ATTENION This appliance is not intended for use by person with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given...

Page 4: ...120 12 0 6 2 0 240 50 Table 1 Figure 1 1 Frame 2 Service panel for water level sensor 3 Auto drain motor 4 Drainage valve 5 Connector 6 T pipe 7 inlet magnetic valve 8 Side cover 9 Drainage pipe 10 Pi...

Page 5: ...ontrol Panel 12 Water Tank 13 Safety Valve MAIN PCB CONTROLLER POWER SUPPLY 13 Figure 2 2 Controller parameters and dimension Model Controller model Controlling time range minutes Temperature display...

Page 6: ...tallation No block valve should be installed in the steam pipelines Strictly no blocked or blended pipe otherwise have negative affect on the flow of steam and condensate The steam pipelines should be...

Page 7: ...4 i Install the generator on the wall drill two small holes on the wall insert the expansion screws and then hang the generator on those screws ii Install the generator on the ground or deck Install...

Page 8: ...L WIRE CONTROLLER WALL CONDUIT SENSOR WIRE CONNECTOR 2P CONTROL WIRE CONNECTOR 6P SEALING GLUE Figure 4 Figure 5 TEMP SENSOR IMMOBILIZING PLATE IMMOBILIZING SCREW WALL SENSOR WIRE Figure 6 4 Installat...

Page 9: ...pe is required to drain water to the drainage All inlet water pipes and steam pipelines should be built according to the National Standard refer to Figure 7 and this should be done before sealing the...

Page 10: ...and repair After the installation of the pipeline and electrical circuits careful checking must be performed before switch on the generator The generator has been carefully installed checked and test...

Page 11: ...60Hz power supply connect one of the live wires to the terminal labeled as L1 connect the other live wire to the terminal labeled as L2 and connect the ground wire to the terminal labeled as 240VAC60...

Page 12: ...L TEMP SWITCH HEATING ELEMENTS CONTROLLER WATER LEVEL SENSOR K3 K1 K4 CON1 K2 ZQJ FB4 PCB GND V12 K2 K4 K6 K1 K5 K3 L1 240VAC60Hz L2 No 100615 GND K3 K5 K1 K6 K4 K2 GND LOW Water level Probe DRAIN HIG...

Page 13: ...K1 K3 K5 K6 K3 K2 K1 K6 K5 CON1 K4 J1 1 K4 K1 J3 J7 LAMP J6 D VALVE J5 IN VALVE ON SW2 ON SW1 J1 TEST D1 D2 D3 D4 P2 P1 P3 D5 D6 J2 BT1 K3 JUMP N L POWER IN 45min DR ZQJ0806 GND HIGH DRAIN Water leve...

Page 14: ...remaining working time is within range of 40 50 minutes all LEDs are on when the remaining working time is within range of 50 60 minutes The default working time is 45 minutes If the system is in lon...

Page 15: ...temperature and time setting otherwise if the system is shut off automatically when setting time is up system will adapt the previous temperature and time setting Then system begins to heat up and pro...

Page 16: ...r ON OFF button is pressed system will drain automatically and displays d on the LCD The drainage valve and the drainage pump will be turned on to drain After a while the system will open the inlet va...

Page 17: ...blue wire and the two white wires respectively Take off all the wires screw out the water level sensor and screw in the new water level sensor until the bottom of the plastic nut reaches the same hei...

Page 18: ...magnetic valve 4 If the system keeps on heating up even if the current temperature is more than 4 above the setting value with the indicator on carefully test the relays on the sub board and change th...

Page 19: ...d altered damaged is not covered either Using in a salty environment or any other extreme corrosive condition is not covered by the warranty After the free warranty period services are still available...

Page 20: ...Calor de Hogar Av Tecnol gico 735 PB San Salvador Tizatlalli Metepec 52172 Edo de M xico Tel fono 722 216 3330 55 1163 6038 www calordehogar com servicio calordehogar om c ventas calordehogar com...

Reviews: