CHAPTER 3    FUNCTIONS AND OPERATION 

 

1.

 

DISPLAY PANNEL   

Temperature: 

The LCD will display the temperature measured by the temperature sensor in the 

range of 43

℉~

140

Set  temperature: 

The  temperature  setting  range  is  95

℉~

131

  and  indicated  by  the  5  red 

LEDs besides the LCD. The bottom LED is on when temperature is 95

; the bottom two LEDs are 

on when the temperature is within range of 97

℉~

104

; three LEDs are on when temperature is 

within  range  of    106

℉~

113

;four  LEDs  are  on  when  temperature  is  within  range  of  115

℉~

122

;  all  LEDs  are  on  when  temperature  is  within  range  of  124

℉~

131

.  The  default  setting 

temperature is 109

Set  time: 

The maximum setting time is 60 minutes and the remaining time is indicated by the 5 

red LEDs besides the LCD. The bottom LED is on when the remaining working time is 20 minutes 
or  below;  the  bottom  two  LEDs  are  on  when  the  remaining  working  time  is  within  range  of 
20~30minutes;  three  LEDs  are  on  when  the  remaining  working  time  is  within  range  of 
30~40minutes;  four  LEDs  are  on  when  the  remaining  working  time  is  within  range  of    40

50 

minutes; all LEDs are on when the remaining working time is within range of 50~60 minutes. The 
default  working  time  is  45  minutes.  If  the  system  is  in  long-term  working  mode,  the  top  LED 
blinks.   

Hint message:   

1)

 

Temperature is lower than 43

LCD displays “

-

L

”, detected by the temperature sensor. 

2)

 

Temperature  is  higher  than  140

LCD  displays  “

-

H

”,  detected  by  the        temperature     

sensor, all heating elements stop working. 

3)

 

Water  supply  fault: 

LCD  displays  “

-

 

E

”.  This  message  appears  when  the  water               

level  is  lower  than  the  minimum  water  level  10  minutes  after  the  system  is  started  and  the 
water inlet valve is opened, or the water level is lower than the desired level 3 minute after the 
water supplementing order is given. It indicates faults of the water supply system, all heating 
elements stop working.   

 

4)

 

Drainage:

  LCD  displays  “

-

d

”,  indicating  automatic  draining  after  the  pre-set  job  is  done 

(

ON/OFF

  button  is  pressed  or  setting  time  is  up),  then  the  whole  system  will  shut  down 

automatically. 

 

5)

 

Connection error:

 LCD displays “

EE

” showing any connection error between the controller 

and the main PCB. 

 

6)

 

Heating up:

 indicated by the three-color LED on the left of the panel with label “

 

Summary of Contents for NTC-60

Page 1: ...Calor de Hogar Av Tecnol gico 735 PB San Salvador Tizatlalli Metepec 52172 Edo de M xico Tel fono 722 216 3330 55 1163 6038 www calordehogar com servicio calordehogar om c ventas calordehogar com...

Page 2: ...Content 1 Introduction 2 Chapter 1 Parameters 3 Chapter 2 Installation and Cautions 5 Chapter 3 Functions and Operation 12 Chapter 4 Maintenance 14 Chapter 5 Troubleshooting 15 Chapter 6 Warranty and...

Page 3: ...ual for further reference ATTENION This appliance is not intended for use by person with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given...

Page 4: ...120 12 0 6 2 0 240 50 Table 1 Figure 1 1 Frame 2 Service panel for water level sensor 3 Auto drain motor 4 Drainage valve 5 Connector 6 T pipe 7 inlet magnetic valve 8 Side cover 9 Drainage pipe 10 Pi...

Page 5: ...ontrol Panel 12 Water Tank 13 Safety Valve MAIN PCB CONTROLLER POWER SUPPLY 13 Figure 2 2 Controller parameters and dimension Model Controller model Controlling time range minutes Temperature display...

Page 6: ...tallation No block valve should be installed in the steam pipelines Strictly no blocked or blended pipe otherwise have negative affect on the flow of steam and condensate The steam pipelines should be...

Page 7: ...4 i Install the generator on the wall drill two small holes on the wall insert the expansion screws and then hang the generator on those screws ii Install the generator on the ground or deck Install...

Page 8: ...L WIRE CONTROLLER WALL CONDUIT SENSOR WIRE CONNECTOR 2P CONTROL WIRE CONNECTOR 6P SEALING GLUE Figure 4 Figure 5 TEMP SENSOR IMMOBILIZING PLATE IMMOBILIZING SCREW WALL SENSOR WIRE Figure 6 4 Installat...

Page 9: ...pe is required to drain water to the drainage All inlet water pipes and steam pipelines should be built according to the National Standard refer to Figure 7 and this should be done before sealing the...

Page 10: ...and repair After the installation of the pipeline and electrical circuits careful checking must be performed before switch on the generator The generator has been carefully installed checked and test...

Page 11: ...60Hz power supply connect one of the live wires to the terminal labeled as L1 connect the other live wire to the terminal labeled as L2 and connect the ground wire to the terminal labeled as 240VAC60...

Page 12: ...L TEMP SWITCH HEATING ELEMENTS CONTROLLER WATER LEVEL SENSOR K3 K1 K4 CON1 K2 ZQJ FB4 PCB GND V12 K2 K4 K6 K1 K5 K3 L1 240VAC60Hz L2 No 100615 GND K3 K5 K1 K6 K4 K2 GND LOW Water level Probe DRAIN HIG...

Page 13: ...K1 K3 K5 K6 K3 K2 K1 K6 K5 CON1 K4 J1 1 K4 K1 J3 J7 LAMP J6 D VALVE J5 IN VALVE ON SW2 ON SW1 J1 TEST D1 D2 D3 D4 P2 P1 P3 D5 D6 J2 BT1 K3 JUMP N L POWER IN 45min DR ZQJ0806 GND HIGH DRAIN Water leve...

Page 14: ...remaining working time is within range of 40 50 minutes all LEDs are on when the remaining working time is within range of 50 60 minutes The default working time is 45 minutes If the system is in lon...

Page 15: ...temperature and time setting otherwise if the system is shut off automatically when setting time is up system will adapt the previous temperature and time setting Then system begins to heat up and pro...

Page 16: ...r ON OFF button is pressed system will drain automatically and displays d on the LCD The drainage valve and the drainage pump will be turned on to drain After a while the system will open the inlet va...

Page 17: ...blue wire and the two white wires respectively Take off all the wires screw out the water level sensor and screw in the new water level sensor until the bottom of the plastic nut reaches the same hei...

Page 18: ...magnetic valve 4 If the system keeps on heating up even if the current temperature is more than 4 above the setting value with the indicator on carefully test the relays on the sub board and change th...

Page 19: ...d altered damaged is not covered either Using in a salty environment or any other extreme corrosive condition is not covered by the warranty After the free warranty period services are still available...

Page 20: ...Calor de Hogar Av Tecnol gico 735 PB San Salvador Tizatlalli Metepec 52172 Edo de M xico Tel fono 722 216 3330 55 1163 6038 www calordehogar com servicio calordehogar om c ventas calordehogar com...

Reviews: