1142 Radio Portable Manual - O&M Manual V6
Z:\AA MANUALS & INSTRUCTIONS 2017\1142 Radio System\1142 Radio Portable Manual - O&M Manual V6.docx
Page
8
of
20
Radio ceiling mounted pull switch
When the orange cord is pulled this unit will send a high level call alert to
the 1142RXmaster. This unit complies with the relevant regulations for this
application.
Cancelling at source
To cancel an alert at the ceiling mounted pull switch pull the cord four
times in quick succession. The reassurance lights will stop flashing and the
alert will have cleared from the 1142RX master panel.
Disabled toilet wall mounted Call alert button
These units operate along the same lines as the other wall call units.
When either button is pressed a high level alert will be sent to the
1142RX master. For disabled toilet applications this unit is supplied with
an orange pull cord and triangle.
Cancelling at source
To cancel an alert at the call unit press and hold
both buttons
. The
reassurance lights will stop flashing and the alert will have cleared from
the 1142RX master panel.
Installation & Maintenance of the System
Silent Test & RSSI (radio signal strength indicator) Mode
To activate the RSSI test mode, press the RSSI/Test mode switch at the bottom right of the
receiver. This mode can only be activated when there is no activity on the system.
To exit this mode, press the RSSI switch again. The RSSI test mode can be exited at any time.
Up to 50 signal strength reports can be shown at any one time.
Before the RSSI test for signal strength can be carried out the 1142RX Portable master should be
placed in the position where it is to be used. When in RSSI mode take the applicable Call alert
button to the location where it is to be used. Press one of the buttons on the Call alert button.
Check the value that is on the 1142RX display. A value ranging from 200
–
45 will be displayed
PAN IC
PAN IC