1142RX Engineer’s Menu –
Overview…cont
inued
Mute Time (Mute delay)
•
To disable the ‘MUTE’ switch, select 0 seconds.
•
This timer is adjustable from 0-600 seconds in 60 second increments (11settings).
•
If a new Call alert is placed on the system after the mute button is set, the MUTE will be
overridden.
Relay (Output Type)
•
The 1142RX has an output that can be used with the CAUK 1132 Relay PCB. This output
can be used to control external sounders or interface with third party systems.
•
The latch option should be used with Beacon Sounders and third party systems
equipment. This will hold the output ON until the Call alert is cancelled.
•
The toggle option is used when Call Aid UK over door lamps are connected to the relay.
The over door lamps will follow the pulse rate of the 1142RX internal sounder. The ODLs
are silenced by cancelling the call or by pressing the mute button.