1.  ATTACH DIVERTER TO YOUR TAP – Remove the aerator from tap (pliers may be required), and attach  

diverter valve in its place.  There are adapters supplied in case the diverter does not fit your tap. 
If you have leaks at the diverter, use plumber’s Teflon tape (available at any hardware store for a couple of dollars).

2.  CUT A FOUR INCH LENGTH OF WHITE HOSE  -  Using a very sharp utility knife, cleanly cut a four inch  

length of the white hose. The cleaner you make your cut, the less likely you will experience a leak.  

3.  ATTACH THE IN-LINE PRE-FILTER – 

There is a small black arrow on the pre-filter indicating water flow direction.  
The arrow on the pre-filter will POINT AT YOU IONIZER indicating water  
flowing toward the ionizer. Insert the four inch length you cut into the end  
of the pre-filter making by pushing firmly ensuring the arrow is pointing  
at the end of the four inch hose. The four inch length will be between  
your ionizer and the pre-filter. 

4.  ATTACH THE TAP WATER INLET HOSE TO YOUR IONIZER – 

Attach the free end of the four inch length of white hose with the pre-filter  
attached to the gray port on the bottom of the ionizer. To attach the white inlet  
hose, by pushing it firmly into the grey tap water inlet port.  
(To remove it, press on the end of the fitting and pull it out at the same time). 

5.  POSITION YOUR IONIZER – This can be beside the sink, to the rear of the sink, or on the wall above the 

sink (there are keyhole slots on the back for this). Make sure it is on a hard and level surface

Connect the external valve between the hoses.

If the water pressure is excessively high, adjust the water flow by turning  
the external valve.

To get the proper pH and ORP value of ionized water, set the external valve  
to allow 1.5 liters of water per minute to flow through the ionizer.

How to install the external valve

Installation method

How to Install

To have the pe of ionized water, adjust the volume of water flow to  
the level 2 controlling the external valve.

How To Install

Accessories 

Inlet

Acidic water 
outlet 

pH test kit

Spare adaptor

Hose

Color chart

Manual

1/4” hose

DUST PRE- FILTER

Your new Orion gives you the option of three installation methods: 
1) at your sink attached to your faucet with a diverter, 
2) at your sink but plumbed directly to your cold water line (no diverter) and, 
3)  undersink - completely out of sight with a small dedicated faucet.  

It is recommended that methods 2) & 3) be done by a plumber.

Installation Method 1. 

At the sink with a diverter (easiest)

Summary of Contents for AQUARION

Page 1: ...AQUARION Warning Incorrect installation and or operation could void your valuable warranty Please protect your investment READ THIS MANUAL CAREFULLY Owner s Manual for your new...

Page 2: ...ailable There are many specific uses and benefits of this amazing water so read this manual carefully to learn how to get both optimum performance out of your ionizer and to protect your investment Yo...

Page 3: ...mouth wash It is an excellent astringent use it for washing your face or as a natural after shave This setting has sterilizing properties use it to sterilize cutting boards dish towels etc In the kitc...

Page 4: ...at the electrodes have very sharp points and form valleys Your ionizer employs special electrodes that generate reduced water with optimal ORP and stable pH level Premium filter materials ensure produ...

Page 5: ...lug is firmly and properly inserted into the outlet failure to do so may result in electric shock or fire Do not wash your ionizer by immersion or by pouring water over the main body always unplug you...

Page 6: ...ng your alkaline water glass or ceramic is best Always try and keep your stored water cool and away from direct sunlight You can use plastic but only use lexan number7 or poly bottles Nalge type It is...

Page 7: ...M Names and functions of Parts I Front Back Body Function display panel Flexible stainless steel alkaline water outlet Filter cover Main switch AC Power cord Tap water inlet Acidic water outlet port H...

Page 8: ...the desired level 1 4 Used to select alkaline water and the desired level 1 4 Starts and stops water flow into your ionizer When this light is lit the appliance needs to be serviced Flickers when the...

Page 9: ...bottom of the ionizer To attach the white inlet hose by pushing it firmly into the grey tap water inlet port To remove it press on the end of the fitting and pull it out at the same time 5 POSITION Y...

Page 10: ...ession nut on the back side of the diverter opposite of the diverter lever c Slide this nut over the end of the white hose with the threads positioned so you can screw it back onto the diverter d Push...

Page 11: ...gh the ionizer next time you use the ionizer it will automatically process at Alkaline Level 2 To select a different level depress the ALKALINE button to move to next level until the desired setting l...

Page 12: ...st tubes away from direct sunlight KEEP pH reagent liquid AWAY FROM CHILDREN and OPEN FLAMES For contact with eyes flush liberally with fresh water seek medical help If ingested induce vomiting seek m...

Page 13: ...se while pressing the Power button on the front Depress the ALKALINE button to raise to the desired setting and depress the ACIDIC button to lower to the desired setting To fix the setting you selecte...

Page 14: ...s will release calcium for about 1 2 months depending on amount of use and pH of water Wash the basket and remove all water Add the new calcium beads and close the cap Insert the basket into the calci...

Page 15: ...is not harmful Open the filter housing cover First slide the cover upwards figure 1 Then slide the cover to the left figure 2 and remove it Remove the expired filter Taking hold of the filter securel...

Page 16: ...y naturally FIR produces well documented health benefits and it also has an amazing effect on water The Biostone contains the semi precious gemstone tourmaline in ceramic form so you get FIR on tap No...

Page 17: ...household plumbing Ensure water supply valves are fully open The water pressure in house may be too low The input hose is bent kinked or therwise restricted Straighten the bent hose Low output of alka...

Page 18: ...33 34 A L K A L I N E I O N I C W A T E R S Y S T E M MEMO AQUARION...

Page 19: ......

Reviews: