A L K A L I N E   I O N I C W A  T E R  S Y S T E M

3.  CUT A FOUR INCH LENGTH OF WHITE HOSE 

Using a very sharp utility knife, cleanly cut a four inch length  
of the white hose. The cleaner you make your cut,  
the less likely you will experience a leak.  
You will use this piece in the next step. 

4.  ATTACH THE IN-LINE PRE-FILTER   

There is a small black arrow on the pre-filter indicating 
water flow direction.  
The arrow on the pre-filter will POINT AT YOU IONIZER  
indicating water flowing toward the ionizer. Insert the four inch  
length you cut into the end of the pre-filter making by pushing  
firmly ensuring the arrow is pointing at the end of the four inch hose.  
The four inch length will be between your ionizer and the pre-filter.

5.  ATTACH THE FOUR INCH WHITE HOSE TO YOUR IONIZER 

Attach free end of the four inch length of the hose into the gray port 
on the bottom of the ionizer by pushing it firmly into the grey tap water inlet port.  
(To remove it, press on the end of the fitting and pull it out at the same time). 

6.  POSITION YOUR IONIZER     

This can be beside the sink, to the rear of the sink.  
Make sure it is on a hard and level surface. 

7.  ATTACH THE GRAY ACIDIC OUTLET HOSE   

The ACIDIC OUTLET port is on the lower right corner of the back of the ionizer, and is labeled with a red sticker.  
First slide, one of the small squeeze clamps over the end of the hose.  
To make it easier to attach, soak the hose in a cup of warm water for 20-30 seconds. 
Firmly push the hose all the way onto the gray outlet port. Squeeze the clamp and slide it over the port. 
Ensure the opposite end runs down into the sink.  
Cut the hose to a convenient length. 

8. CONNECT THE POWER CORD to an appropriate GFI outlet.

9.  INSTALL FLEXIBLE STAINLESS STEEL SPOUT  

Screw this into the port on the top of the ionizer. Do not over tighten.

How to Install

6.  ATTACH THE TAP WATER INLET HOSE TO THE DIVERTER – 

a.  Insert the long length of white hose into the free end of the pre-filter  

(see photo). 

b.  Remove the small compression nut on the back side of the diverter  

opposite of the diverter lever. 

  c.  Slide this nut over the end of the white hose with the threads positioned so 

you can screw it back onto the diverter. 

  d.  Push the white hose firmly onto the nipple, and then screw the compression  

nut back onto the nipple. Make sure the nut is screwed firmly in place, but  
do not over tighten. If you are having trouble getting hose on to the nipple,  
try soaking it in hot water for a minute.

7.  ATTACH THE GRAY ACIDIC OUTLET HOSE .   

The ACIDIC OUTLET port is on the lower right corner of the back of the ionizer,  
and is labeled with a red sticker. First slide, one of the small squeeze  
clamps over the end of the hose.  
To make it easier to attach, soak the hose in a cup of warm water for 20-30  
seconds. Firmly push the hose all the way onto the gray outlet port.  
Squeeze the clamp and slide it over the port.  
Ensure the opposite end runs down into the sink. Cut the hose to a convenient length. 

8. CONNECT THE POWER CORD to an appropriate GFI outlet.

9.  INSTALL FLEXIBLE STAINLESS STEEL SPOUT – 

Screw this into the port on the top of the ionizer.  
Do not over tighten. 

1.  SPLIT YOUR COLD WATER SUPPLY LINE – 

This can be accomplished in a variety of ways depending on how your plumbing is configured. 
Most commonly, you would install a “T” junction in the cold water line.  
“T” junctions are available at any good hardware store and are inexpensive.  
Take the white hose when you purchase the “T” to ensure the proper size fitting. 

2.  ATTACH THE TAP WATER INLET HOSE TO THE “T” JUNCTION – 

You will need a hole through which you can route the white hose from the “T” to your ionizer. 
Most newer sinks have cutouts that will work for this.  
Pull the hose up to the counter.

Installation Method 2. 

At the sink under direct main pressure (more difficult) 

Undersink Installation 

 (most difficult)

Undersink installations can only be accomplished with an Undersink Conversion kit. 
Your ionizer will require a very specialized faucet and a variety of other parts. 
The conversion kit comes complete with everything needed to complete this type of installation.  
It is recommended that a plumber perform this type of installation. 
Please contact your dealer.

Summary of Contents for AQUARION

Page 1: ...AQUARION Warning Incorrect installation and or operation could void your valuable warranty Please protect your investment READ THIS MANUAL CAREFULLY Owner s Manual for your new...

Page 2: ...ailable There are many specific uses and benefits of this amazing water so read this manual carefully to learn how to get both optimum performance out of your ionizer and to protect your investment Yo...

Page 3: ...mouth wash It is an excellent astringent use it for washing your face or as a natural after shave This setting has sterilizing properties use it to sterilize cutting boards dish towels etc In the kitc...

Page 4: ...at the electrodes have very sharp points and form valleys Your ionizer employs special electrodes that generate reduced water with optimal ORP and stable pH level Premium filter materials ensure produ...

Page 5: ...lug is firmly and properly inserted into the outlet failure to do so may result in electric shock or fire Do not wash your ionizer by immersion or by pouring water over the main body always unplug you...

Page 6: ...ng your alkaline water glass or ceramic is best Always try and keep your stored water cool and away from direct sunlight You can use plastic but only use lexan number7 or poly bottles Nalge type It is...

Page 7: ...M Names and functions of Parts I Front Back Body Function display panel Flexible stainless steel alkaline water outlet Filter cover Main switch AC Power cord Tap water inlet Acidic water outlet port H...

Page 8: ...the desired level 1 4 Used to select alkaline water and the desired level 1 4 Starts and stops water flow into your ionizer When this light is lit the appliance needs to be serviced Flickers when the...

Page 9: ...bottom of the ionizer To attach the white inlet hose by pushing it firmly into the grey tap water inlet port To remove it press on the end of the fitting and pull it out at the same time 5 POSITION Y...

Page 10: ...ession nut on the back side of the diverter opposite of the diverter lever c Slide this nut over the end of the white hose with the threads positioned so you can screw it back onto the diverter d Push...

Page 11: ...gh the ionizer next time you use the ionizer it will automatically process at Alkaline Level 2 To select a different level depress the ALKALINE button to move to next level until the desired setting l...

Page 12: ...st tubes away from direct sunlight KEEP pH reagent liquid AWAY FROM CHILDREN and OPEN FLAMES For contact with eyes flush liberally with fresh water seek medical help If ingested induce vomiting seek m...

Page 13: ...se while pressing the Power button on the front Depress the ALKALINE button to raise to the desired setting and depress the ACIDIC button to lower to the desired setting To fix the setting you selecte...

Page 14: ...s will release calcium for about 1 2 months depending on amount of use and pH of water Wash the basket and remove all water Add the new calcium beads and close the cap Insert the basket into the calci...

Page 15: ...is not harmful Open the filter housing cover First slide the cover upwards figure 1 Then slide the cover to the left figure 2 and remove it Remove the expired filter Taking hold of the filter securel...

Page 16: ...y naturally FIR produces well documented health benefits and it also has an amazing effect on water The Biostone contains the semi precious gemstone tourmaline in ceramic form so you get FIR on tap No...

Page 17: ...household plumbing Ensure water supply valves are fully open The water pressure in house may be too low The input hose is bent kinked or therwise restricted Straighten the bent hose Low output of alka...

Page 18: ...33 34 A L K A L I N E I O N I C W A T E R S Y S T E M MEMO AQUARION...