Operating instructions
EVS17/07-DS/IU und EVS17/12-DS/IU
Trautmann GmbH & Co. KG
-Apparatebau
CALIRA
Lerchenfeldstr. 9 87600 Kaufbeuren Tel.08341/9764-0 Fax 08341/67806
Internet: http://www.calira.de Email: [email protected]
30
Assembly
Safety instructions
Setting up
Connecting the device to the power supply must comply with the
applicable national installation regulations.
This device contains components that may generate electric arcing and
sparks. Therefore when operating the device in a garage or a similar
location, it must be contained in a room or housing designed for this
purpose!
When using this device in caravans and mobile homes, the device and
the battery must be installed with physical separation between them and
in well-ventilated boxes!
The assembly and connection of electric devices should always be
carried out by qualified personnel!
Always make sure that the power supply is disconnected! Pull out the
mains plug!
When connecting the device, use only the supplied parts and the
specified cable cross-sections and fuses!
Only use suitable and undamaged tools.
Only connect the device according to the supplied connection diagram!
Remove the items packed separately (accessories) from the main carton, and
check them for completeness.
4 fastening screws with washers
2 mains cables, length 1 m, assembled
1 fuse extraction pliers
1 plug connector, 6-pole
1 plug connector, 12-pole
18 contact pins
1 operating instructions.