2
2
Control
Board Light Status Chart
No.
Name
Status/Light
1
CL
ON when CLOSE input is activated
2
PED-SW
3
SAFETY
ON when Stand By, OFF when SAFETY LOOP input is activated
4
PHANTOM
5
EXIT LOOP
ON when EXIT LOOP input is activated
6
LIMIT1
ON when limit nut is activating the limit 1 switch
7
LIMIT2
ON when limit nut is activating the limit 2 switch
8
RADIO
ON when the RADIO input is activated
9
RESET
ON when circuit board is RESET
10
POWER
ON when STAND BY, blinks when motor is on
11
B.L-POWER
ON when back up battery is fully charged, blinks when low battery
12
M/S LINK
Blinks when master/slave communication is active
13
TIMER
Blinks when TIMER is counting down to close automatically
14
OPENING
ON when gate is in the open cycle
15
CLOSING
ON when gate is in the close cycle
16
MON-FAULT
ON when photo eye has malfunctioned
17
MON-OPEN
ON when photo eye is functioning during open cycle
18
MON-CLOSE
ON when photo eye is functioning during close cycle
Features
ON when incoming signal is detected
ON when STAND BY, OFF when the STOP input is activated or foot pedeal
is pressed down.