OUTPUT PHASE 

ADJUSTMENT ON CURRENT LIMIT BOARD 

A R17 

B R46 
C R72 

 

Restore the correct phase configuration by performing the following steps: 

1. 

Depress the MNU key several times until the first Menu screen is displayed as illustrated 
below: 

    

SNC 

01 

    

RNG 

04 

2. 

Enter the key sequence:    959 ENT 

3. 

Depress the MNU key several times until the Configuration Menu Screen is displayed as 
illustrated below: 

   CFG 

16 

 ALM 

17 

   FLM 

18 

 CLM 

19 

Enter the following key sequence to display the Configuration Screen: 

Enter the following key sequence to display the Configuration Screen: 

   16 

ENT 

6. 

While viewing the Configuration Screen, depress the C key followed by entering the value 
120, the PRG and ENT keys. 

 

3