User Manual – Rev B
FCS Series II
3.6 Connectors - Rear Panel
A number of connectors are located on the rear panel of the FCS18 cabinet.
3.6.1 AC
put Connector – INPUT – TB1
In
See section 3.4 for details on connecting AC input power. Labeled INPUT TB1.
INPUT.
Direction
Connection Description
1 ØA
Input
AC
Line
2 ØB
Input
AC
Line
3
ØC
Input
AC Line
4 GND
Chassis
Ground
Table 3-5: AC Input Terminal Block Connection Description
xternal Sense Connector – SENSE – TB2
3.6.2 E
The external sense connections for Phase A, B and C in three-phase mode and Phase A in
single phase mode
MUST
be connected for correct operation in external sense mode. Sense
connections must be made at the MASTER FCS unit for a multi-box FCS system. There is NO
internal sense mode on the FCS Series II.
Pin
Description
1
Phase A sense Hi
2
Phase B sense Hi
3
Phase C sense Hi
4 Neutral
sense
Table 3-6: Ext
nnector
3.6.3 Output Termi
Block
UT - TB3
ernal Sense Co
nal
– OUTP
Each FCS chassis has a single AC output terminal block. The output terminal block junction box
must be clos
(covere
ll times ex
reconnecting an EUT. The terminal blocks
are large enough to accommodate required wire gauge sizes. The terminal block is located in
the lower left corner on the rear panel of the unit. (Looking from the back).
ed
d) at a
cept when
Connector
Terminal
Mode
FCS Output
TB3
1
3 Phase & 1 Phase
ØA
2
3
Phase
ØB
3
3 Phase
ØB
4
Common / Neutral
NEUT
Table 3-7: Output Terminal connections.
California Instruments
37
Summary of Contents for FCS Series II
Page 4: ...User Manual Rev B FCS Series II California Instruments 4...
Page 27: ...User Manual Rev B FCS Series II California Instruments 27...
Page 89: ...FCS Series II 89 Figure 5 1 FCS System Block Diagram User Manual Rev B California Instruments...
Page 95: ...User Manual Rev B FCS Series II Figure 6 1 Calibration Setup California Instruments 95...