California Air Tools 200CR Owner'S Manual Download Page 15

15

Customer Support: 1-866-409-4581

Exclusions 

In addition to the foregoing disclaimers, limitations and terms, this limited warranty shall not apply to and does not cover accessories, nor 
does it cover products that are in any way subject to any of the following: 

1.

 Improper setup, installation or storage. 

2.

 Lack of proper maintenance and service. 

3.

 Accident, damage, abuse or misuse. 

4.

 Abnormal operating conditions or applications. 

5.

 Repair or modification by customer or any third party without written consent of California Air Tools Inc. 

6.

 Use under operating conditions or in applications not recommended by California Air Tools Inc. 

7.

 Normal wear. 

8.

 The use of accessories or attachments not recommended by California Air Tools Inc. 

9.

 Acts of God. 

The application of these exclusions will be determined at the sole discretion of California Air Tools Inc. 

 

Registration 

Warranty registration with California Air Tools Inc. is required on all products. 

You can mail the enclosed registration form or register on-line at www.californiaairtools.com. 

Click on the Customer Service Tab and the Product Registration Tab. 

 

Trouble Shooting & Maintenance Guide

 

California Air Tools provides information on our website WWW.CALIFORNIAAIRTOOLS.COM. 

The trouble Shooting & Maintenance Guide provides valuable information regarding set-up, operation, maintenance and trouble shooting. 

Please visit our website and view these videos for beneficial information. 

 

Service or Parts 

Warranty is also available by keeping and showing your original receipt from the date of purchase to an  

Authorized California Air Tools Service Center. 

 

For customer service (M - Th)  8am - 4pm Pacific Time)  

1-866-409-4581  

 

or visit 

 

WWW.CALIFORNIAAIRTOOLS.COM 

 

 

Go to the “Contact Us” Tab 

 

Click on “Service” or  the “Parts” Buttons for the Fastest Service.

 

 

 

 

Summary of Contents for 200CR

Page 1: ...RA QUIET OIL FREE AIR COMPRESSOR MOTOR PUMP OWNER S MANUAL CALIFORNIA AIR TOOLS 200CR 2 0 HP 110 VOLTS 60 HERTZ 6 00 CFM 40 PSI 5 00 CFM 90 PSI WWW CALIFORNIAAIRTOOLS COM Customer Support 1 866 409 45...

Page 2: ...____________________________10 Daily Operation________________________________10 MAINTENANCE _________________________________11 Changing the Air Filter__________________________11 Cleaning __________...

Page 3: ...Department Phone 1 866 409 4581 Online WWW CALIFORNIAAIRTOOLS COM Please provide the information below Model number and Serial number and specifications shown on the Model number Serial number plate P...

Page 4: ...compressor after it has thoroughly cooled down FIRE HOT SURFACE WARNING Flying objects can cause injury to the eyes head and other parts of the body Air powered equipment and power tools are capable...

Page 5: ...ever make adjustments to the factory set pressures Never exceed manufacturer s maximum allowable pressure rating attachments Because of extreme heat do not use plastic pipe or lead tin solder joints f...

Page 6: ...provide important safety and maintenance information These labels should be considered as permanent parts of the air compressor Should any of these labels become illegible damaged or removed please c...

Page 7: ...7 Customer Support 1 866 409 4581...

Page 8: ...Always use the air filter properly installed Use caution to minimize risk of fire or explosion It is normal for the air compressor motor and pressure switch to produce sparks while operating If sparks...

Page 9: ...se a dedicated 110v 60hz 15 amp power supply Max 14 gauge 100ft extension cord Min 3000 Watt Running Generator WIRING MOTOR PUMP Wiring Instructions Black White Wires hot To Power Supply Green Wire To...

Page 10: ...n the power switch to the ON position 7 Do not use continously running for more than 8 hours of continuous running at 90 PSI and 12 hours at 40 PSI Shutting down the compressor 1 Turn the power switch...

Page 11: ...e solvent Do not use flammable liquids such as gasoline or alcohol Always keep parts clean from dirt and dust for better performance Use a blow gun to blow out any dust or debris inside the motor STOR...

Page 12: ...ut Contact Customer Support The motor does not start and makes a humming noise Capacitor is burned out Contact Customer Support The motor does not start or starts slowly Low voltage supply to the moto...

Page 13: ...osts Thermal Overload Protector 125 PSI Maximum Pressure Ports 1 2 NPT Output Elbow 3 8 NPT 110v 60 hz Low Amp Draw 14 Amps Power Requirements Dedicated 15 amp outlet 3000 Watt running Generator Exten...

Page 14: ...ghts and you may also have other rights which may vary from state to state Disclaimer of Other Warranties To the fullest extent permitted by applicable law this limited warranty is exclusive and expre...

Page 15: ...ermined at the sole discretion of California Air Tools Inc Registration Warranty registration with California Air Tools Inc is required on all products You can mail the enclosed registration form or r...

Reviews: