GAS REQUIREMENTS (LP or NG Natural Gas)
Verify the type of gas supply to be used, either
Natural
or
LP
, and make sure the marking on the appliance rating plate
agrees with that of the supply. The rating plate is located underneath the unit bottom. Never connect an unregulated gas
line to the appliance. You must use the gas regulator provided with the unit, even if the supply is controlled.
An installer-supplied gas shut-off valve must be installed in an easily accessible location. All installer supplied parts must
conform to local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or the Ca-
nadian Electrical Code, CSA C22.1, and the National Fuel Gas Code, ANSI Z223.1 or CAN/CGA-B149.1 Natural Gas
Installation Code or CAN/CGA-B149.2 Propane Installation Code.
All pipe sealants must be an approved type and resistant to the actions of LP gases. Never use pipe sealant on flare
fittings. All gas connections should be made by a qualified technician and in accordance with local codes and ordinances.
In the absence of local codes, the installation must comply with the National Fuel Gas Code ANSI Z223.1. Gas conver-
sion kits are available from the factory. When ordering gas conversion kits, have the model number, and the type of gas
(natural or LP) from your grill.
TOTAL GAS CONSUMPTION OF THE GRILL WITH ALL BURNERS ON HI:
{ CRG-60R = 60,000 Btu/hr }
The grill and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa.) The grill must be isolated from the gas supply pip-
ing system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 PSIG (3.5 kPa.). The installation of this grill must conform with local codes or, in
the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1. Installation in Canada must be in accordance
with the Standard Can1-b149.1 and/or .2 (installation code for gas burning appliances and equipment) and local codes.