Connector type:
Binder series 712
subminiature circular
connector (socket)
front view
pin no. description
1
n.c.
2
Fault relay circuit (max. ratings: 120V D/C, 100 mA)
3
Fault relay circuit (max. ratings: 120V D/C, 100 mA)
4
Ground
5
Ground
6
n.c
7
+24V Power Supply
Internally the power sensor interconnects RF ground and D/C ground. In order to avoid ground loops, it is
recommended not to connect RF ground and D/C ground at a second point.
The sat-nms PowerSensor is designed to be mechanically mounted with it's RF input connector. For most
setups this will be the most convenient method. However, there are some cases where it is recommended to
fix the PowerSensor with a break at a solid surface:
When operated in an vibrating environment, the sensor may resonate when fixed only with the input
connector. This may result in a inadmissible severe vibration at the power sensor itself.
When the sensor is connected to a SMA connector through an adapter, this connection easily may
break as it is mechanically to strong enough not fix the sensor in safe manner.
(C) 2020, SatService GmbH
www.satnms.com
PS-UM-2002 Page 7/16