PM180 TOUCH SCREEN INTERFACE MODULE

The PM180 is a temperature indicator, data logger, alarm 

unit and configuration tool for Calex infrared temperature 

sensors. It is compatible with all models in the PyroBus and 

PyroMiniBus series, as well as all PyroMini and FibreMini 

models with Modbus output.
The PM180 functions as the Modbus Master on an RS485 

network of up to 6 temperature sensors, and can itself be 

connected as a slave device to another RS485 network via 

a second, isolated Modbus interface. This allows multiple 

PM180 units to be multi-dropped to create a large network of 

sensors and displays.
Optional alarm relay modules allow the PM180 to be connected to alarm equipment such as 

sounders and beacons, and optional analogue output modules allow it to be connected to 

non-Modbus instrumentation.
All the configurable parameters for the hub, the connected sensors and the optional output 

modules are adjustable via the PM180’s built-in resistive touch screen interface, which can be 

operated even with gloves on.
With an optional MicroSD Card inserted, the PM180 functions as a fully-configurable data 

logger.

SPECIFICATIONS

Touch Screen Display

2.83” (72 mm) resistive TFT, 320 x 240 pixels, backlit

Supply Voltage

10 to 30 V DC

Maximum Current Draw

100 mA

Ambient Temperature Range

0°C to 60°C

Relative Humidity

Maximum 95%, non-condensing

Configurable Parameters 

(global)

Temperature units, date and time, data logging, graph 

channels, alarm logging

Configurable Parameters (per 

channel)

Signal processing, emissivity setting, reflected energy 

compensation, alarms, Modbus address

Alarm Configuration

12 alarms (2 per sensor) with adjustable level, 

individually configurable as HI or LO.

Temperature Units

°C or °F selectable

Temperature Resolution

0.1° below 1000°; 1° above 1000°

Signal Processing

Average, peak hold, valley hold, minimum, maximum

Display Sample Period

120 ms per device (720 ms in total for 6 devices)

Compatible Sensor Types

PyroBus (all models),  

PyroMiniBus (all models),  

PyroMini (-BB and -BRT models),  

FibreMini (–BRT models)

Compatible Output Module 

Types

ICP DAS M-7061  12-channel relay output module, 

ICP DAS M-7024  4-channel analogue output module, 

selectable V/mA

Dimensions

98(w) x 64(h) x 36(d) mm excluding cable glands

Weight

280 g

Summary of Contents for PMB201

Page 1: ...PyroMiniBus Series Operator s Guide...

Page 2: ...odel Number 2 1 PMB21 20 1 PMB201 Close Focus 3 5 mm at distance 50 mm PMBXCF General Interface RS485 Modbus RTU Accuracy 1 of reading or 1 C whichever is greater Repeatability 0 5 of reading or 0 5 C...

Page 3: ...e the nominal target spot diameter at any given distance from the sensing head and assume 90 energy Sensors may be used at longer distances than these diagrams show Thread M16 x 1 mm Standard length 1...

Page 4: ...aller than the target We normally recommend that the target should be at least twice the size of the measured spot for maximum accuracy AMBIENT TEMPERATURE The sensor is designed to operate in ambient...

Page 5: ...ckets or cut outs of your own design or you can use the fixed and adjustable mounting bracket accessories which are shown below Note The sensor must be grounded at only one point either the cable shie...

Page 6: ...nterface please see the PM180 section of this Operator s Guide IMPORTANT Do not connect or disconnect Modbus devices with power on Always disconnect power before modifying electrical connections SENSO...

Page 7: ...seconds R W 0x0B 1 Average Temperature R 0x0C 1 Minimum Temperature R 0x0D 1 Maximum Temperature R 0x0E 1 Filtered Temperature R 0x0F 1 Unfiltered Temperature R 0x10 1 Sensor Temperature R 0x11 1 Sta...

Page 8: ...ng Averaging and Hold Processing Unfiltered Temperature The raw measured temperature without Averaging or Hold Processing Sensor Temperature The temperature inside the sensor body this is usually a fe...

Page 9: ...etween moving objects e g on a conveyor or by an obstruction LENS CLEANING Keep the lens clean at all times Any foreign matter on the lens would affect measurement accuracy Blow off loose particles if...

Page 10: ...loves on With an optional MicroSD Card inserted the PM180 functions as a fully configurable data logger SPECIFICATIONS Touch Screen Display 2 83 72 mm resistive TFT 320 x 240 pixels backlit Supply Vol...

Page 11: ...termined time via the Settings menu If the PM180 is connected via the slave interface to another Modbus network logging may also be started remotely by the Modbus Master on that network DIMENSIONS PMB...

Page 12: ...12 ELECTRICAL CONNECTION...

Page 13: ...PM180 is locked and the Settings menu is greyed out To access the Settings menu unlock the PM180 The default password is 1234 After entering the password tap the Unlock icon to unlock the unit The pa...

Page 14: ...0 to 59 R W 0x0012 1 Data acquisition start time Day 1 to 31 R W 0x0013 1 Data acquisition start time Month 1 to 12 R W 0x0014 1 Data acquisition start time Year 2012 to 2105 R W 0x0015 1 Alarm log se...

Page 15: ...20 5 0x1500 5376 Example To read the Filtered Temperature on a PyroMiniBus sensor in position 4 on the PM180 as shown above read from register 0x0E 0x1400 0x140E decimal 5134 For information on the Mo...

Page 16: ...Calex Electronics Limited PO Box 2 Leighton Buzzard Bedfordshire England LU7 4AZ Tel 44 0 1525 373178 Fax 44 0 1525 851319 Email mail calex co uk Online www calex co uk Issue E Jul 2018...

Reviews: