calentador Supreme 11e Installation & Maintenance Download Page 2

SUPREME E 

2

 

cod. A73020280 - Rev. 01 - 02/2013 

 

 

 

 

 

Temperature probe disconnected/open

 

Temperature read by the DHW sensor < 10°C

 

 

 

 

Probe or cable short circuited.

 

Temperature read by the DHW sensor > 99°C

 

 

 

1.  GENERAL INSTRUCTIONS

 

  Carefully read and follow the instructions contained in this booklet. 

  After installing the unit, inform the user about its operation and give him this manual, which 

is an integral and essential part of the product and must be kept for future reference. 

  Installation  and  maintenance  must  be  carried  out  by  professionally  qualified  personnel,  in 

compliance  with  the  current  regulations  and  according  to  the  manufacturer's  instructions. 
Do not carry out any operation on sealed adjustment parts. 

  Incorrect  installation  or  inadequate  maintenance  can  result  in  damage  or  injury.  The 

Manufacturer declines any liability for damage due to errors in installation and use, or failure 
to follow the instructions. 

  Before carrying out any cleaning or maintenance operation, turn off the gas by means of the 

special shutoff devices. 

  In  case  of  a  fault  and/or  poor  operation,  deactivate  the  unit  and  do  not  try  to  repair  it  or 

directly intervene. 

  Contact  professionally  qualified  personnel.  Any  repair/replacement  of  the  products  must 

only  be  carried  out  by  qualified  personnel  using  original  replacement  parts.  Failure  to 
comply with the above could affect the safety of the unit. 

  This  unit  must  only  be  used  for  its  intended  purpose.  Any  other  use  is  deemed  improper 

and therefore hazardous. 

  The  packing  materials  are  potentially  hazardous  and  must  not  be  left  within  the  reach  of 

children. 

  The unit must not be used by people (including children) with limited physical, sensory or 

mental  abilities or without experience  and knowledge  of it, unless instructed or supervised 
in its use by someone responsible for their safety. 

  The  unit  and  its  accessories  must  be  appropriately  disposed  of,  in  compliance  with  the 

current regulations. 

 

The  images  given  in  this  manual  are  a  simplified  representation  of  the  product.  In  this 
representation there may be slight and insignificant differences with respect to the product 
supplied.

 

2.  OPERATING INSTRUCTIONS 

2.1  Introduction

 

SUPREME  E 

is a high efficiency, instantaneous domestic hot water heater using 

natural gas or propane gas, equipped with an  atmospheric burner with electronic 
switch,  airtight  chamber  and  forced  ventilation.  For  interior  or  partially  protected 
exterior  installation  (in  accordance  with  EN  297/A6)  with  temperatures  no  lower 
than -5ºC.   

 

2.2 

Control panel

 

Panel

 

 

fig. 1 Control panel

 

Panel - legend fig. 1

 

DHW temperature display

 

Fan display 

 

Burner power adjustment

 

Temperature adjustment

 

Flame symbol

 

Indication during operation

 

 

Table. 1 - Display symbols

 

 

 

 

 

 

Symbol flashing: the burner is on.

 

If the burner is off, this symbol is not displayed.

 

 

 

Water heater outlet temperature.

 

 

Stationary symbol. Pressure switch open. Heater switched off (fault)  

Rotating symbol. Heater working, normal operation.  

 

During a DHW demand (generated by drawing domestic hot water), the display 
shows the actual DHW outlet temperature.

 

2.3 Lighting and turning off

 

Preliminary operations and checks

 

1. 

Make sure the hot water taps are closed.

 

2. 

Open the water heater gas supply cock, located on its gas connection.

 

3. 

Check that it is connected to the network. 

 

Lighting

 

Turn the knob to the required water heating level.

 

 

 

fig. 2 Lighting

 

The unit will immediately be ready to operate whenever hot water is drawn.

 

Turning off

 

The  burner  goes  off  automatically  when  the  hot  water  demand 
ceases.

 

No  special  operation  is  needed  in  order  to  carry  out  another  lighting  phase.  To 
completely shut down the unit, turn the knob to position

.

 

 

 

fig. 3 Unit deactivated 

 

In case of prolonged shutdown close the gas cock ahead of the unit. 

 

For long periods of inactivity during the winter months, to avoid frost damage it is 
advisable to drain all the water from the water heater.

 

2.4 Adjustments

 

Manual setting of burner power

 

Use  the  power  adjustment  knob  (ref.  3  -  fig.  1)  to  select  the  water  heater  power, 
minimum  or  maximum  and  intermediate  positions  depending  on  the  required  water 
heating  level.  Turn  the  knob  anticlockwise  and  the  unit  heats  the  water  at  maximum 
power.  If  the  temperature  is  too  high,  for  example  in  the  summer,  or  when  a  reduced 
flow of not very hot water is necessary, turn the knob clockwise. This reduces the power 
(and gas consumption). In the position 

  the unit is deactivated.

 

Temperature setting

 

The water temperature can be easily set with the temperature selector: turn it to the 

right to increase the temperature, or to the left to decrease. 

 

fig. 4 Temperature adjustment 

 

Faults 

After making the adjustments described above, the water heater is ready to operate in 
completely automatic mode. When a hot water tap is opened, an intermittent discharge 
is generated  on the  ignition  electrode, which causes lighting  of the burner  and,  at the 
same time, operates the gas extraction fan.

 

All the electronic models have an ionisation electrode inserted in the burner to control 
correct flame presence. In case of malfunction or no gas with subsequent burner shut- 
down, close the hot water tap.

 

It  is  then  necessary  to  eliminate  the  cause  or  the  element  preventing  the  gas  from 
reaching the water heater, e.g. inadvertent closing of the gas cock, empty gas cylinder, 
etc.

 

Water heater shutdown status is deactivated by closing and opening the hot water tap. 

Repeat  the  operation  if  the  delivery  of  hot  water  is  not  restored  after  eliminating  the 

cause

 

and opening the hot water tap. If the fault persists, contact the After-Sales Technical

 

Service.

 

 

Table. 2 - Table of faults 

 

 

 

 

 

Temperature probe disconnected/open

 

Temperature read by the DHW sensor < 10°C

 

 

 

 

Probe or cable short circuited.

 

Temperature read by the DHW sensor > 99°C

 

 

 

Summary of Contents for Supreme 11e

Page 1: ...SUPREME E EN INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...

Page 2: ...tionary symbol Pressure switch open Heater switched off fault Rotating symbol Heater working normal operation During a DHW demand generated by drawing domestic hot water the display shows the actual DHW outlet temperature 2 3 Lighting and turning off Preliminary operations and checks 1 Make sure the hot water taps are closed 2 Open the water heater gas supply cock located on its gas connection 3 C...

Page 3: ... Ask a qualified technician to check the efficiency and compatibility of the earth installation The manufacturer accepts no responsibility for damage caused by a lack of earth connection for the unit The heater is supplied with a cable to connect it to the electrical network Y type with a pin The supply cable for the unit must not be replaced by the user If the cable is damaged turn off the unit a...

Page 4: ...5 meq Without diaphragm Table 5 Accessories Losses in meq Air intake Steam output Vertical Horizontal Ø 80 TUBE 0 5 m M H 1KWMA38A 0 5 0 5 1 1 m M H 1KWMA83A 1 1 2 2 m M H 1KWMA06K 2 2 4 BEND 45 H H 1KWMA01K 1 2 2 2 45 M H 1KWMA65A 1 2 2 2 90 H H 1KWMA02K 2 3 90 M H 1KWMA82A 1 5 2 5 90 M H outlet to check 1KWMA70U 1 5 2 5 SLEEVE With outlet to check 1KWMA16U 0 2 0 2 for condensation discharge 1KWM...

Page 5: ...pe of gas used Apply the sticker contained in the conversion kit near the data plate as proof of the conversion 4 2 Commissioning Before lighting the water heater Check the tightness of the gas system Fill the hydraulic system and make sure the air in the water heater and system is completely vented Make sure there are no water leaks in the system and unit Check the correct gas pressure value Make...

Page 6: ...es and leaks The burner and exchanger must be clean and free of deposits For possible cleaning do not use chemical products or wire brushes The electrodes must be free of deposits and correctly positioned Fig 16 Electrode positioning The gas and water systems must be tight The gas flow and pressure must match that given in the respective tables 5 TECHNICAL DATA AND CHARACTERISTICS Table 3 Key of f...

Page 7: ...pressure bar 0 2 0 2 DHW flow rate Dt 25 C l min 11 13 7 DHW flow rate Dt 50 C l min 5 5 6 9 D Protection rating IP X5D X5D Fume thermostat intervention temperature C 90 Empty weight kg 11 12 Type of unit C12 C22 C32 C42 C52 C62 C72 C82 B22 PIN CE 0461CL0983 Gas category II 2H 3 Fume and air flow rate SUPREME 11 E SUPREME 14 E Fume temperature at Qn C Fume flow rate Air flow rate Fume temperature ...

Page 8: ...used by The electrical supply of equipment by generators or any other system that is not a stable electrical network with sufficient capacity Products that have undergone any repair not carried out by Cointra s OFFICAL Technical Department and or personnel authorised by Cointra Godesia Corrosion deformation etc caused by inadequate storage Handling of the product by anyone outside of Cointra durin...