calentador Supreme 11e Installation & Maintenance Download Page 1

 
 
 
SUPREME E

 

 

 

 

 

 
 

EN 

INSTRUCTIONS FOR USE, INSTALLATION AND  MAINTENANCE 

Summary of Contents for Supreme 11e

Page 1: ...SUPREME E EN INSTRUCTIONS FOR USE INSTALLATION AND MAINTENANCE ...

Page 2: ...tionary symbol Pressure switch open Heater switched off fault Rotating symbol Heater working normal operation During a DHW demand generated by drawing domestic hot water the display shows the actual DHW outlet temperature 2 3 Lighting and turning off Preliminary operations and checks 1 Make sure the hot water taps are closed 2 Open the water heater gas supply cock located on its gas connection 3 C...

Page 3: ... Ask a qualified technician to check the efficiency and compatibility of the earth installation The manufacturer accepts no responsibility for damage caused by a lack of earth connection for the unit The heater is supplied with a cable to connect it to the electrical network Y type with a pin The supply cable for the unit must not be replaced by the user If the cable is damaged turn off the unit a...

Page 4: ...5 meq Without diaphragm Table 5 Accessories Losses in meq Air intake Steam output Vertical Horizontal Ø 80 TUBE 0 5 m M H 1KWMA38A 0 5 0 5 1 1 m M H 1KWMA83A 1 1 2 2 m M H 1KWMA06K 2 2 4 BEND 45 H H 1KWMA01K 1 2 2 2 45 M H 1KWMA65A 1 2 2 2 90 H H 1KWMA02K 2 3 90 M H 1KWMA82A 1 5 2 5 90 M H outlet to check 1KWMA70U 1 5 2 5 SLEEVE With outlet to check 1KWMA16U 0 2 0 2 for condensation discharge 1KWM...

Page 5: ...pe of gas used Apply the sticker contained in the conversion kit near the data plate as proof of the conversion 4 2 Commissioning Before lighting the water heater Check the tightness of the gas system Fill the hydraulic system and make sure the air in the water heater and system is completely vented Make sure there are no water leaks in the system and unit Check the correct gas pressure value Make...

Page 6: ...es and leaks The burner and exchanger must be clean and free of deposits For possible cleaning do not use chemical products or wire brushes The electrodes must be free of deposits and correctly positioned Fig 16 Electrode positioning The gas and water systems must be tight The gas flow and pressure must match that given in the respective tables 5 TECHNICAL DATA AND CHARACTERISTICS Table 3 Key of f...

Page 7: ...pressure bar 0 2 0 2 DHW flow rate Dt 25 C l min 11 13 7 DHW flow rate Dt 50 C l min 5 5 6 9 D Protection rating IP X5D X5D Fume thermostat intervention temperature C 90 Empty weight kg 11 12 Type of unit C12 C22 C32 C42 C52 C62 C72 C82 B22 PIN CE 0461CL0983 Gas category II 2H 3 Fume and air flow rate SUPREME 11 E SUPREME 14 E Fume temperature at Qn C Fume flow rate Air flow rate Fume temperature ...

Page 8: ...used by The electrical supply of equipment by generators or any other system that is not a stable electrical network with sufficient capacity Products that have undergone any repair not carried out by Cointra s OFFICAL Technical Department and or personnel authorised by Cointra Godesia Corrosion deformation etc caused by inadequate storage Handling of the product by anyone outside of Cointra durin...