background image

4

Thermostatic control, 
1161xxA series

Thermostatic control with check valve, 
1161xxAC series

Technical specifications

Materials

 

Body:                                                                      DZR low-lead brass EN 12165 CW724R

Adjustable cartridge: 

Stainless steel & copper

Springs: 

Stainless steel EN 10270-3 (AISI 302)

Hydraulic seals: 

peroxide-cured EPDM

Adjustment knob: 

ABS

Performance

Suitable fluid: 

water 

Max. working pressure: 

230 psi (16 bar)

Max. differential pressure: 

15 psi (1 bar)

Adjustable temperature range: 

95–140°F (35 – 60°C)

Factory setting: 

130°F (55°C)

Disinfection temperature:  

1162xx series-160°F (70°C)
1166xx series-140°F (60°C)

Closing temperature:  

1162xx series-170°F (75°C)
1166xx series-150°F (65°C)

Max. inlet temperature: 

    195°F (90°C)

Cv (Kv) max:                                                                                                           2.1 (1.8)

Cv (Kv) dis:                                                                                                   1.2 (1.0)

Cv (Kv) min:                                                                                                0.23 (0.2)

Cv (Kv) design:                                                                                           0.52 (0.45)

Certifications

1. Complies with codes IPC, IRC, UPC and NPC. 

2. ICC-ES certified to NSF/ANSI 61 (180°F/82°C Commercial Hot), file PMG-1512.

3. NSF/ANSI 372, low lead certified by ICC-ES, file PMG-1360.

Connections

Main connnections: 

½” NPT female

¾” NPT female

Temperature gauge/probe pocket:                                                       Ø 10 mm metric

 

Temperature gauge code 116010

Scale:                                                                                         30 - 180°F (0–80°C)

Diameter:                                                                                              1½” (40 mm)

Stem diameter:                                                                                      0.35” (9 mm)

Summary of Contents for ThermoSetter 116 Series

Page 1: ...actuator disinfection function models w and w o temperature gauge w and w o check valve connections NPT female 1166 series ThermoSetter w disinfection function by pass cartridge 140 F 60 models w and...

Page 2: ...ubricity so that care must be exercised not to over tighten joints Failure to follow these instructions could result in property damage and or personal injury WARNING System fluids are under pressure...

Page 3: ...la temp rature peuvent tre dangereux tre s r que la pression a t r duite z ro et la temp rature du syst me est inf rieure 100 F 38 C Le non respect de ces instructions peut entra ner des dommages mat...

Page 4: ...C Factory setting 130 F 55 C Disinfection temperature 1162xx series 160 F 70 C 1166xx series 140 F 60 C Closing temperature 1162xx series 170 F 75 C 1166xx series 150 F 65 C Max inlet temperature 195...

Page 5: ...using flow and thus temperature to increase back to the set temperature as shown in curve 1 If temperature exceeds the set point the plug stays in the minimum closed position as shown in curve 2 The b...

Page 6: ...ath up until the by pass temperature is attained shown in curve 3 If the temperature continues rising beyond this point the flow is reduced through the by pass port to allow thermal balancing even dur...

Page 7: ...case the minimum head loss is produced during this thermal disinfection process Installation Before installing the ThermoSetter flush the pipes to make sure that impurities in system will not interfe...

Page 8: ...NPT F 4 5 7 16 3 1 7 0 75 116150A C NPT F 4 5 5 8 3 1 5 0 70 116151A C NPT F 4 5 5 8 3 1 5 0 70 Models with check valve tail piece C end to end dimension is B with integral outlet temperature gauge B...

Page 9: ...mal working conditions T 10 F Determine the pressure drop across the valve by selecting the branch design GPM on the graph X axis draw a vertical line up to the design curve then go across to the Y ax...

Page 10: ...e this is the minimum flow rate at the mixing valves in the central heating system Adjustment locking After adjusting the temperature the setting can be locked at the desired value using the adjustmen...

Page 11: ...ion control cartridge can be removed from the valve body for periodic inspection cleaning or replacement Innsulation shell The ThermoSetter thermal balancing valve can be supplied with an optional ins...

Page 12: ...0 F 130 F 140 F 120 F NOTE Do not set at temperatures 120 F if anti scald valves are not installed at the xtures Hot water recirculation with thermal balancing valves 230 V 50 Hz THERMAL DISINFECTION...

Reviews: