CALEFFI ThermoSetter 116 Series Installation, Commissioning And Servicing Instructions Download Page 2

2

    

 

SAFETY INSTRUCTION

This safety alert symbol will be used in this manual to draw attention to safety related instructions. 

When used, the safety alert symbol means 

ATTENTION! BECOME ALERT! YOUR SAFETY IS 

INVOLVED! FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN A SAFETY 

HAZARD.

LEAVE THIS MANUAL FOR THE USER.

Caleffi shall not be liable for damages resulting from stress corrosion, misapplication or misuse of it products.

CAUTION:

 All work must be performed by qualified personnel trained in the 

proper application, installation, and maintenance of systems in accordance 

with all applicable codes and ordinances.

CAUTION:

 Over-tightening and breakage can occur with the use of Teflon

®

pipe joint compounds. Teflon

®

 provides lubricity so that care must be

exercised not to over-tighten joints. Failure to follow these instructions

could result in property damage and /or personal injury.

WARNING:

 System fluids are under pressure or temperature can be

hazardous. Be sure the pressure has been reduced to zero and the

system temperature is below 100°F (38°C). Failure to follow these

instructions could result in property damage and/or personal injury.

WARNING:

 

This product can expose you to chemicals including lead, which is known 

to the State of California to cause cancer and birth defects or other reproductive harm. 

For more information go to www.P65Warnings.ca.gov.

CAUTION: 

Make sure that all the connecting pipework is water tight.

CAUTION:

 If the series ThermoSetter balancing valve is not installed, 

commissioned and maintained properly, according to the instructions contained 

in this manual, it may not operate correctly and may endanger the user.

Summary of Contents for ThermoSetter 116 Series

Page 1: ...and w o temperature gauge w and w o check valve connections and NPT female 1163 series ThermoSetter w actuator disinfection function models w and w o temperature gauge w and w o check valve connection...

Page 2: ...ubricity so that care must be exercised not to over tighten joints Failure to follow these instructions could result in property damage and or personal injury WARNING System fluids are under pressure...

Page 3: ...la temp rature peuvent tre dangereux tre s r que la pression a t r duite z ro et la temp rature du syst me est inf rieure 100 F 38 C Le non respect de ces instructions peut entra ner des dommages mat...

Page 4: ...table temperature range 95 140 F 35 60 C Factory setting 130 F 55 C Disinfection temperature 160 F 70 C Closing temperature 170 F 75 C Max inlet temperature 195 F 90 C Cv Kv max 2 1 1 8 Cv Kv dis 1 2...

Page 5: ...3 5 4 6 7 8 1 Function B Automatic thermostatic disinfection The 1162xx series operating characteristic curves for operating mode B are curves 1 2 3 and 4 When a temperature higher than about 155 F 68...

Page 6: ...case the minimum head loss is produced during this thermal disinfection process Installation Before installing the ThermoSetter flush the pipes to make sure that impurities in system will not interfe...

Page 7: ...750 0 700 15 20 B B Code A B B C D Wt lb kg 116140A C NPT F 4 5 7 16 3 1 7 0 75 116141A C NPT F 4 5 7 16 3 1 7 0 75 116150A C NPT F 4 5 5 8 3 1 5 0 70 116151A C NPT F 4 5 5 8 3 1 5 0 70 Models with c...

Page 8: ...mal working conditions T 10 F Determine the pressure drop across the valve by selecting the branch design GPM on the graph X axis draw a vertical line up to the design curve then go across to the Y ax...

Page 9: ...e this is the minimum flow rate at the mixing valves in the central heating system Adjustment locking After adjusting the temperature the setting can be locked at the desired value using the adjustmen...

Page 10: ...ion control cartridge can be removed from the valve body for periodic inspection cleaning or replacement Innsulation shell The ThermoSetter thermal balancing valve can be supplied with an optional ins...

Page 11: ...120 F if anti scald valves are not installed at the xtures Hot water recirculation with thermal balancing valves 230 V 50 Hz THERMAL DISINFECTION CONTROL UNIT B A S INTERFACE Master mixing valve for...

Page 12: ...Caleffi North America Inc 3883 W Milwaukee Road Milwaukee WI 53208 T 414 238 2360 F 414 238 2366 4 3 19...

Reviews: