background image

3

Technical specifications

Materials
Shut-off valves

Body:

brass EN 12165 CW617N

Check valve:

brass EN 12164 CW614N

Temperature gauge:

steel / aluminium

Air separator device

Body:

brass EN 12165 CW617N

Instrument holder

Body:

brass EN 12165 CW617N

Seals:

EPDM

O-Rings:

EPDM

Flow meter

Body:

brass EN 12165 CW617N

Transparent level gauge:

PSU

Flow indicator:

brass EN 12164 CW614N

Hydraulic seals:

EPDM

Insulation

Material:

EPP

Average thickness:

30 mm

Density:

45 kg/m

3

Working temperature range:

-5–120°C

Thermal conductivity:

0,037 W/(m·K) at 10°C

Reaction to fire (UL 94):

class HBF

Performance

Medium:

water, glycol solutions

Max. percentage of glycol:

50%

Max. working temperature:

- deaerator side flow:

160°C

- pump side return:

110°C

Max. working pressure:

10 bar

Safety relief valve working temperature range:

-30–160°C

Safety relief valve setting: 6 bar (for other settings, see 253 series)

Check valve min. opening pressure (

p): 2 kPa (200 mm w.g.)

Working temperature range of shut-off and check valve:

-30–160°C

Working temperature range of flow meter :

-10–110°C

Flow rate adjustment:

1–13 l/min

Flow rate indicator accuracy:

±10%

Pressure gauge scale:

0–10 bar

Temperature gauge scale:

0-160°C

Connections:

3/4” F

Hose connection:

3/4” M

Fill/drain connections:

with Ø 15 mm hose connection

Grundfos Solar 15-65 pump

Body:

cast iron GG 15/20

Electric supply:

230 V - 50 Hz

Max. pressure:

10 bar

Max. temperature:

110°C

Protection class:

IP 42

Digital regulator

Electric supply:

230 V - 50 Hz

Nominal power consumption:

1,5 VA (12 V (ac))

4 Pt1000 probe inputs

2 relay outputs with semiconductor with contact rating:

1 A

2 temperature probes with working range:

-50–200°C

Probe cable working temperature range:

-50–70°C

2 temperature probes with working range:

-50–200°C

Probe cable working temperature range:

-50–180°C

Ambient temperature range:

0–40°C

Protection class:

IP 20

Dimensions:

172 x 111 x 49 mm

Head available at the circulation unit connections

0

0

H (mm w.g.)

G (m

3

/h)

H (kPa)

0

1

2

3

UPS 15-65

6

5

4

3

2

1

60

50

40

30

20

10

0,2

0,4

0,6

0,8

1,0

1,2

1,4

0

0

H (mm w.g.)

G (m

3

/h)

H (kPa)

0

1

2

3

UPS 15-65

6

5

4

3

2

1

60

50

40

30

20

10

0,2

0,4

0,6

0,8

1,0

1,2

1,4

Power consumption

0

P (W)

G (m

3

/h)

20

30

40

50

60

70

80

0,2

0,4

0,6

0,8

1,0

1,2

1,4

1

2

3

UPS 15-65

268

series

Flow rate adjustment range 1

13 l/min

269

series

Flow rate adjustment range 1

13 l/min

Summary of Contents for DeltaSol 268050

Page 1: ...devices for optimum control of the circuit are fitted in the units They are available with flow and return connection or with return connection only Some versions are also complete with the digital r...

Page 2: ...ges with hydraulic leaks and damage to property and or personal injury Water temperatures exceeding 50 C may cause severe burns When installing commissioning and servicing take the necessary precautio...

Page 3: ...ment 1 13 l min Flow rate indicator accuracy 10 Pressure gauge scale 0 10 bar Temperature gauge scale 0 160 C Connections 3 4 F Hose connection 3 4 M Fill drain connections with 15 mm hose connection...

Page 4: ...mperature indication 13 Regulating keys 14 Temperature probe 15 Stainless steel probe pocket code 257004 optional 16 Hose connection only for versions with DeltaSol C regulator 1 2 3 4 5 8 9 11 10 16...

Page 5: ...d in the assembly phase at the factory However when commissioning it is necessary to check the seal of the fittings performing a pressure test Make the electrical connections of the system as specifie...

Page 6: ...e deaerated again both in the highest point and on the air separator on the versions where this is contemplated Once deaeration has been completed check the system pressure and if necessary restore to...

Page 7: ...m every six months by using the deaerator A Full closing and opening of the valve The valve can be completely opened or closed A slot on the obturator stem indicates the status of the valve Correction...

Page 8: ...e nor me ISPESL 0 2 4 6 8 10 bar CL 2 5 1 13 11 9 7 5 3 l min 1 13 11 9 7 5 3 l min 1 13 11 9 7 5 3 l min a Shut off valve Pump Air vent Expansion vessel Temperature gauge Safety relief valve Automati...

Reviews: