background image

Normal soap build-up will require water replacement regularly enough that mineral deposits normally are not a problem.
Occasionally, high iron or copper content in the water may produce green or brown stains on the spa. A stain and scale inhibitor may help to reduce these metals.

NOTe:

 Well water may contain high concentrations of minerals. The use of a low water volume, extra-fine pore water filter will help to remove many of the larger particles 

during the filling of the spa.

2.  Foam Inhibitors 

(uSE 

MONarCH

 dEFoMEr)

Spa water requires changing due to the buildup of soap in the water. Typically, soap will cause the spa water to foam when the jets are used. Soap is introduced into the 

spa water from two sources: users’ bodies, which retain a soap residue after showering, and swimming apparel, which retains soap after washing.
Foam inhibitors can suppress foam, but cannot remove soap from the water. Soap is very difficult to remove from the water because soap is not oxidized by any 

chemical added to the spa. Only ozone can oxidize soap.
Eventually the soap build-up in the water will be concentrated, resulting in an unclean feeling on the bather’s skin, which is impossible to remedy. When this occurs, it’s 

time to drain and refill the spa. Depending on the soap input, the water should last about 4 months before needing to be drained.

MONARCh

 

OzONE SYSTEM (

OPTIONAl

)

The 

MONarCH

 high output ozone system is the only ozone purification system approved for installation in your 

VaCaNza

 

 

series spa. The 

MONarCH

 ozone system 

utilizes Corona Discharge (CD) technology to produce a higher concentration of ozone than is produced by competing ultraviolet light (UV) ozone systems.
The 

MONarCH

 high output ozone system greatly enhances the quality of the spa water when used to supplement the spa owner’s regular water maintenance 

program. Contrary to some information circulated throughout the pool and spa industry regarding ozone systems, ozone can not be used as a single-source sanitizer, 

water clarifier, anti-foamer, and mineral chelating agent. Watkins Manufacturing Corporation recommends following the 

FrOG

  sanitizing system when using an ozone 

purification system to assure water sanitation and the highest quality of purified water.

Cleaning the Ozone Injector

On occasion, a mineral build up may clog the ozone injector, causing a lack of flow or low flow, of ozone bubbles. To prevent this, refer to the following instructions to 

clean the injector:
1.  Disconnect power to the spa.
2.  Access the equipment compartment. 
3.  Place 16 ounces of white vinegar into a container such as a cup or bucket. Place the container on the equipment compartment floor. NOTE: White vinegar will not 

damage any of the spa components.

4.  Carefully loosen the long tubing to the bottom of the ozonator.

 a liquid substance may be found inside the tubing. If a liquid substance is present, Be 

CerTaIN NOT TO COMe IN CONTaCT WITH THe lIQUId (See WarNING BelOW).

5.  Place the end of the tubing into the vinegar, making certain that the end of the tubing sits at the bottom of the container.
6.  Reconnect power to the spa.
7.  Run the spa until all 16 ounces of the vinegar are gone. This should allow an ample flow of vinegar to be run through the injector and clear the blockage.
8.  Disconnect power to the spa.
9.  Remove the empty cup or bucket.
10.  Reinstall the tubing to the bottom of the ozonator.
11.  Close the equipment compartment door.
12.  Reconnect power to the spa.
The 

MONarCH

 ozone system is practically maintenance-free because it is located within the spa’s equipment compartment. If bubbles are appearing at the spa’s heater 

return, but the water is not as clear as usual, then the operation of the ozone generator should be checked by your dealer.

WarNING:

 Contact your dealer if your spa requires troubleshooting beyond the scope of this manual. 

MONarCH

 ozone systems should only be serviced by a 

qualified technician.

WarraNTY NOTe:

 Cleaning of the ozone injector is not covered under the warranty. Refer to the Ozone section of this manual for ozone injector cleaning instructions..

WaTer QUalITY aNd MaINTeNaNCe

27

Nitric acid accumulates in the air lines of the ozonator and injector. Nitric 

acid will cause severe chemical burns if direct skin contact is made, so 

always wear protective gloves, glasses and clothing when working on the 

ozonator or injector lines. To prevent inhalation or ingestion of the nitric acid, 

dO NOT blow or inhale with your mouth to any of the adapters, fittings or 

tubing of the ozonator or injector air lines.

WARNING

WARNING

Summary of Contents for vacanza series

Page 1: ...VACANZA SERIES 2 0 1 4 O W N E R S M A N U A L...

Page 2: ...SPA MODEL SERIAL NUMBER ____________________________ COVER SERIAL NUMBER ________________________________ In most cities and counties permits will be required for the installation of electrical circu...

Page 3: ...ONS Control Operation 14 System Mode 15 Manual Clean Cycle 15 Tools Menu 15 Audio Menu Optional 17 Air Control 19 Hydrotherapy Jets 19 Waterfall Valve 19 WATER QUALITY AND MAINTENANCE Water Terminolog...

Page 4: ...tion of this important safety device test according to the following instructions per electrical configuration Cord Connected 115 volt 20 amp models The GFCI is located at the end of the power cord Be...

Page 5: ...ion fitting There is a danger of slipping and falling Remember that wet surfaces can be very slippery Take care when entering or exiting the spa Never operate spa if the suction fittings are broken or...

Page 6: ...the control box by the spa owner will void the warranty If you have an operational problem carefully go through the steps outlined in the Troubleshooting section If you are not able to resolve the pro...

Page 7: ...manual and printed instructions on all water care chemical products packaging Test the water regularly to ensure proper levels of sanitizers pH and other water care requirements Drain clean and refil...

Page 8: ...he spa s safety features Improper wiring may also cause electrocution risk of fire and other risks of injuries Please read and follow the electrical installation requirements and instructions for your...

Page 9: ...to the wiring diagram below 1 Connect the 8 AWG WHITE NEUTRAL wire from the Neutral Ground Bar on the main electrical service to the WHITE NEUTRAL Panel Neutral Pigtail of the subpanel 2 Connect the...

Page 10: ...ALS adjust Total Alkalinity TA to 80 180 ppm Calcium Hardness CH to 50 150 ppm then spa water pH to between 7 2 and 7 8 These procedures are listed in the Water Quality and Maintenance section OPERATI...

Page 11: ...5 volt 20 amp electrical configuration the heating system does not operate simultaneously with the high speed pump On the other hand on the 230 volt system the heating system does operate simultaneous...

Page 12: ...AdaptaFlo jets 7 AdaptaSsage Jets 8 Outlet for optional ozone 9 Drain suction fitting 10 Pillow 11 Waterfall valve 12 Acquarella Waterfall 13 FROG Palatino Marino 1 1 2 4 7 9 5 1 1 6 10 8 8 9 3 11 12...

Page 13: ...IT IN THE FILTER COMPARTMENT AREA THIS IS NOT A SEAT Sitting in this area can cause Restriction of filter pump suction vacuum Damage to components Both can result in bodily harm Should damage occur to...

Page 14: ...r optional ozone 10 Drain suction fitting 11 Pillow 12 Grab Rail 13 FROG aventine 1 2 3 4 6 7 8 7 12 5 11 6 8 10 9 8 13 WARNING DO NOT SIT IN THE FILTER COMPARTMENT AREA THIS IS NOT A SEAT Sitting in...

Page 15: ...aSsage Jets in back right 2 AdaptaFlo Jets and 1 Euro Jet in right center 4 Euro Jets in footwell PALATINO MARINO System 1 8 Euro Jets in back left 2 AdaptaFlo Jets in back center Acquarella Waterfall...

Page 16: ...taFlo Jet and 1 AdaptaSsage in front left tarino System 1 Menu A Diverter in position 8 Euro Jets in back left 2 AdaptaSsage Jets in back right Lounge Acquarella Waterfall 2 Euro Jets in footwell 3 Eu...

Page 17: ...T MENUS 14 AVENTINE System 1 2 Euro Jets in back left 3 AdaptaFlo Jets in back left 2 Euro Pulse Jets in arm rests 4 Euro Jets in back right 2 AdaptaFlo Jets in back right 1 AdaptaFlo Jet in front rig...

Page 18: ...ystem 1 jet pump runs on high speed 3rd press System 1 System 2 jet pumps run on high speed 4th press System 2 jet pump runs on high speed 5th press Both Systems jet pumps are off Tarino Aventine Spa...

Page 19: ...ng features SPA Lock and Temperature Lock are enabled from the control panel by pressing the SET button until the Tools menu is illuminated Then press the TEMP button to enter the TOOLS submenus Use t...

Page 20: ...leep mode to work in the evening hours the spa must be powered up in the early morning hours The Sleep Mode will always be active the 6 12 hours between the end of F2 and the begining of F1 depending...

Page 21: ...stem ON Press the TEMP button to display PWR and turn the audio system OFF Audio power must be ON to advance to the other audio screens IMPORTANT The power can take up to a few seconds to turn on or o...

Page 22: ...button to raise the Bass or press TEMP button to lower the Bass TO ADJUST BAlance From the SETUP menu 1 Press the TEMP button to display one of four audio sources IPOD TV AUX BLUE 2 Press the SET but...

Page 23: ...jets provide a rotating massage pattern Euro Jets The Euro Directional jets with eyeball nozzles deliver a direct more focused massage The Euro Pulse jet features a special insert that creates a soft...

Page 24: ...ramines and will not alter the water s pH Pathogen A microorganism such as bacterium that cause disease pH The measure of the spa water s acidity and alkalinity The recommended pH for the spa water is...

Page 25: ...substance can be identified Don t let chemicals get on surrounding surfaces or landscaping Don t use a vacuum cleaner to clean up chemical spills Never smoke around chemicals Some fumes can be highly...

Page 26: ...lution a mixture of 75 hard and 25 soft water will usually yield a reading within the correct range If soft water is not available or practical for you a stain and scale inhibitor should be added to t...

Page 27: ...Plus or sodium dichlor chlorine Sodium dichlor may be a more appropriate weekly shock for those users that experience heavy bather load conditions The following optional products can be used in conjun...

Page 28: ...er to establish the correct setting on cartridges for User Load and Usage Time versus Sanitizer Needed User Load is the spa is the number of times anyone enters the spa Usage Time is simply the amount...

Page 29: ...n incorrect product such as tri chloro which has a very low pH 2 6 dissolves too quickly in hot water resulting in extremely high levels of chlorine and is designed for concrete or plaster swimming po...

Page 30: ...em to assure water sanitation and the highest quality of purified water Cleaning the Ozone Injector On occasion a mineral build up may clog the ozone injector causing a lack of flow or low flow of ozo...

Page 31: ...e chemically induced spa surface blistering chemical abuse very quickly WATER QUALITY AND MAINTENANCE Spa water maintenance troubleshooting guide Cloudy Water Water Odor Chlorine Odor Musty Odor Dirty...

Page 32: ...ldera Spa Water Maintenance program are needed to protect the user from water borne pathogens disease causing microbes and to prevent corrosion of spa components Question Why isn t water chemistry dam...

Page 33: ...illow retainers to slip into the recess in the back of the pillow 4 Keeping the pillow slightly bent slide the other pillow retainer into the recess in the back of the pillow 5 After all the pillow re...

Page 34: ...the outlet of the hose to an appropriate draining area Spa water with a high sanitizer level may harm plants and grass 3 Open the valve by turning the knob The spa will drain by gravitational flow IMP...

Page 35: ...re install your filter and follow the Start up and Refill Procedures in the Operating Instructions section of the Owner s Manual IMPORTANT Always keep spa covered when not in use whether it is empty...

Page 36: ...conds to reset the heater high limit If tripping continues clean the filter then if tripping still occurs call for service Water temperature significantly different from display temperature Display sh...

Page 37: ...pump s to allow the air to escape When water is present hand tighten the union Turn power back on activate the pump and check to make sure union is tight enough to keep it from leaking Re install equi...

Page 38: ...r purchaser of the Caldera spa when purchased and originally installed within the boundaries of the United States This warranty begins on your delivery date of the spa but in no event later than one y...

Page 39: ......

Page 40: ...lbs 120 lbs per Square foot 230 volt 50 amp Single phase GFCI circuit Marino Model MRN 7 0 x 7 0 36 65 square feet 4 000 360 gallons 836 lbs 4 888 lbs 120 lbs per Square foot 230 volt 50 amp Single p...